T
Fields on this screen include:
7-18
Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
— Y: Remote alarm indication signal received at the G.703 interface
— L: Loss of signal detected at the G.703 interface
— E: Excessive error rate threshold exceeded
— F: Frame synchronization bit error detected
— V: Line code violation detected
— None: No significant events have occurred
Field . . .
Contains . . .
Current Interval Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds
(15 minutes). This counter resets every 15 minutes.
When zero, the port is disabled.
Error Events Counter
A running total of CRC errors. Range 0– 65535. This counter
resets when the statistics are cleared. When zero, the port is
disabled.
Current Interval
Performance data for the current 15-minute interval. When
blank, the port is disabled.
Interval xx
Historical performance data for up to 96 15-minute intervals
(24 hours). When blank, the port is disabled.
Worst Interval
The number of the interval with the worst (highest) performance
data statistics. If two or more intervals are equal, the oldest
interval is displayed. When zero, the port is disabled.
Tot
A running total of the performance statistics.