Paradyne 8779 User Manual page 78

Tdm sdsl termination units
Table of Contents

Advertisement

7. Monitoring and Troubleshooting
Table 7-6.
7-26
Troubleshooting (2 of 2)
Symptom
Possible Cause
An LED is not lit.
LED is out.
T
Not receiving data.
T
T
Not receiving data on
The DSL line rate does not
one or more time slots.
support the number of DSL
time slots defined.
The associated port is
administratively disabled.
May 2002
The network or DTE port
cables are not connected
(check front panel LEDs
for more information).
A test is being executed
on the unit (check the
TEST LED on the front
panel).
The far-end device is
offline.
Solutions
Run the Lamp Test. If the LED
in question does not flash with
the other LEDs, then contact
your service representative.
T
Check network and DTE port
cables.
T
Check Health and Status
menu.
T
Run Loopback tests. Refer to
Chapter 8, Testing
.
T
Stop the test or wait for the
test to end.
T
Make sure the far-end device
is on.
Match the number of DSL time
slots to the DSL line rate. See
Table A-2, Payload Rates and
DSL Line Rates for Model
8777,
Table A-3, Payload Rates and
DSL Line Rates for
G.703, for
information about payload rates
for different DSL line rates.
Check the Display LEDs screen
to determine if the port is
disabled. Enable the port if
necessary using the Network,
DSX-1, or G.703 Interface
Options screen.
8700-A2-GB20-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

U87778777

Table of Contents