Table 7-2.
7-8
Self-Test Results Messages (2 of 2)
Message
What Message Indicates
FPGA Failed
The Field Programmable
Gate Array serving all ports
failed.
G.703 Failed, Pt 1
The unit failed to loop data on
the G.703 on Port n .
Memory
The unit failed memory data
Test n Fail
verification (Test 1) or
memory address verification
(Test 2).
Passed
No errors were detected.
PLD Failed, Pt n
An error was detected in a
Programmable Logic Device.
TSI CPLD Fail
The Complex Programmable
Logic Device serving the
Timeslot Interchanger failed.
TSI Fail
The Timeslot Interchanger
failed.
May 2002
What To Do
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
No action is needed.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.