B. Standards Compliance for SNMP Traps
Enterprise-Specific Traps
The enterpriseSpecific trap indicates that an enterprise-specific event has
occurred. The Specific-trap field identifies the particular trap that occurred. The
following table lists the enterprise-specific traps supported by the unit:
B-4
SNMP Trap
enterprisePrimaryClock
Fail(1)
enterpriseSelfTestFail(2)
enterpriseDeviceFail(3)
enterpriseSecondaryClock
Fail(4)
enterpriseTestStart(5)
enterpriseConfigChange(6) The configuration changed
May 2002
Description
The unit has lost its primary
clock source.
No variable bindings.
A hardware failure of the
unit is detected during the
unit's self-test. The trap is
generated after the unit
completes initialization.
Variable bindings:
T
devSelfTestResults
An internal device failure.
No variable bindings.
The unit has lost its
secondary clock source.
No variable bindings.
A test is running.
Variable bindings:
T
devSelfTestResults
T
ifIndex (RFC 2863)
T
ifAdminStatus
(RFC 2863)
T
ifOperStatus (RFC 2863)
T
ifType (RFC 2863)
T
ifTestType (RFC 2863)
via the user interface. The
trap is sent after
60 seconds have elapsed
without another change.
This suppresses the
sending of numerous traps
when multiple changes are
made in a short period of
time, as is typically the case
when changing
configuration options.
No variable bindings.
Possible Cause
Hardware failure in the unit
or the clock source.
Failure of one or more of the
unit's hardware components.
Operating software has
detected an internal device
failure.
Hardware failure in the unit
or the clock source.
At least one test has been
started on an interface.
Configuration has been
changed via the ATI.