Interface Options (Model 8777) - Paradyne 8779 User Manual

Tdm sdsl termination units
Table of Contents

Advertisement

DSX-1 Interface Options (Model 8777)
For the Model 8777's DSX-1 Interface Options, refer to
Options – Model
menu selection sequence:
Table A-4. DSX-1 Interface Options – Model 8777 (1 of 2)
8700-A2-GB20-40
8777. To access the DSX-1 Interface Options screen, follow this
Main Menu
Configuration
main/config/DSX-1
Slot: 18
Port 2
DSX-1 INTERFACE OPTIONS
Port Status:
Line Coding
Line Framing:
Line Equalization:
Excessive Error Rate Threshold:
Primary Clock Source:
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
Save
Port Status
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether the port can be configured and used.
Enable – The port can be configured and used.
Disable – The port cannot be configured or used. Configuration fields for the port are
inaccessible, no alarms or traps associated with the port are generated, and the LED
associated with the port is OFF.
NOTE: Cross-connections are not cleared when a port is disabled.
Line Coding Format
Possible Settings: AMI, B8ZS
Default Setting: B8ZS
Specifies the line coding format to be used by the DSX-1 interface.
AMI – Indicates the line coding format used by the DSX-1 interface is Alternate Mark
Inversion (AMI).
B8ZS – Indicates the line coding format used by the DSX-1 interface is B8ZS.
May 2002
Table A-4, DSX-1 Interface
Current Configuration
DSX-1
Enable
B8BS
ESF
0 -133
1E-4
DSX-1
A. Configuration Options
Model: 8777
MainMenu