Table 4-14 DST120X (200V) emission compliance (single and
three phase drives
Motor cable length
(m)
3
Using internal filter:
0 to 7
7 to 9
9 to 11
>11
Using external filter:
0 to 20
20 to 100

Table 4-15 DST140X (400V) emission compliance

Motor cable length
(m)
3
Using internal filter:
0 to 6
6 to 12
12 to 14
E2U
>14
Using external filter:
0 to 20
20 to 70
70 to 100
I
Key to Table 4-14 and Table 4-15
(shown in decreasing order of permitted emission level):
E2R
EN 61800-3:2004 second environment, restricted distribution
(Additional measures may be required to prevent interference)
E2U
EN 61800-3:2004 second environment, unrestricted distribution
I
Industrial generic standard EN 61000-6-4:2007
EN 61800-3:2004 first environment restricted distribution (The
following caution is required by EN 61800-3:2004)
This is a product of the restricted distribution class according
to IEC 61800-3. In a residential environment this product may
cause radio interference in which case the user may be
required to take adequate measures.
CAUTION
R
Residential generic standard EN 61000-6-3:2007
EN 61800-3:2004 first environment unrestricted distribution
EN 61800-3:2004 defines the following:
The first environment is one that includes residential premises. It
also includes properties directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for residential purposes.
The second environment is one that includes all establishments
other than those directly connected to a low-voltage power supply
network which supplies buildings used for residential purposes.
Restricted distribution is defined as a mode of sales distribution in which
the manufacturer restricts the supply of equipment to suppliers,
customers or users who separately or jointly have technical competence
in the EMC requirements of the application of drives.
30
Electrical
Getting
Basic
installation
started
parameters
Switching frequency (kHz)
4
6
8
E2U
E2U
E2U
E2R
E2R
R
I
I
Switching frequency (kHz)
4
6
8
E2U
E2R
E2U
E2R
E2R
E2R
R
I
I
Do not use
www.controltechniques.com
Running the
SMARTCARD
Optimization
motor
Operation
IEC 61800-3:2004 and EN 61800-3:2004
The 2004 revision of the standard uses different terminology to align the
requirements of the standard better with the EC EMC Directive.
Power drive systems are categorized C1 to C4:
12
Category
E2R
Intended for use in the first or second
C1
environments
Not a plug-in or movable device, and
intended for use in the first environment
C2
only when installed by a professional, or
in the second environment
Intended for use in the second
C3
environment, not the first environment
Rated at over 1000V or over 400A,
12
C4
intended for use in complex systems in
the second environment
Note that category 4 is more restrictive than E2R, since the rated current
of the PDS must exceed 400A or the supply voltage exceed 1000V, for
the complete PDS.
N
NOTE
Where the drive is incorporated into a system with rated input current
exceeding 100A, the higher emission limits of EN 61800-3:2004 for the
second environment are applicable, and no filter is then required.
N
NOTE
Operation without an external filter is a practical cost-effective possibility
in an industrial installation where existing levels of electrical noise are
likely to be high, and any electronic equipment in operation has been
designed for such an environment. This is in accordance with EN 61800-
3:2004 in the second environment, with restricted distribution. There is
some risk of disturbance to other equipment, and in this case the user
and supplier of the drive system must jointly take responsibility for
correcting any problem which occurs.
4.12

Serial communications connections

The drive has a serial communications port (serial port) as standard
supporting 2 wire EIA485 communications. Please see Table 4-16 for
the connection details for the RJ45 connector.

Figure 4-9 Location of the RJ45 serial comms connector

Onboard
Advanced
Technical
PLC
parameters
Data
Definition
8
1
Digitax ST User Guide
UL listing
Diagnostics
information
Corresponding
code used
above
R
I
E2U
E2R
Issue: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents