1-1] Slot-Ip-Gw Card Property - Panasonic KX-TDA50 Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Feature Manual References
None
OUS
Takes the channel out of service. This enables a temporary non-use of the port, for example, for the
purpose of repair.
Default
Not applicable.
Value Range
Not applicable.
Maintenance Console Location
2.7.18 [1-1] Slot—T1 Port—Channel Command (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
2.7.17 [1-1] Slot—T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Feature Manual References
None
2.7.19 [1-1] Slot—IP-GW Card Property
The properties of the VoIP Gateway card can be specified.
En-bloc Dialing Setting
Selects the call dialing mode.
Default
Overlap
Value Range
En-bloc: The PBX sends all of the dialed digits at once after the extension user completes dialing.
The PBX recognizes the end of dialing when (1) # is dialed, if programmed, (2) a preprogrammed
telephone number is dialed, or (3) the inter-digit timer expires.
Overlap: The PBX sends dialed digits one at a time.
Maintenance Console Location
2.7.19 [1-1] Slot—IP-GW Card Property
Programming Manual References
2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Extension Inter-digit
2.8.17 [2-9] System Options—Option 2—ISDN en Bloc Dial—[#] as End of Dial for en Bloc mode (KX-
TDA100/KX-TDA200/KX-TDA600 only)
2.7 [1] Configuration
PC Programming Manual