Panasonic KX-TDA50 Programming Manual page 89

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Default
112 ms
Value Range
8 × n (n=3–63) ms
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
Flash Timing - Range
Specifies the maximum length that a signal sent from an SLT can be for the PBX to recognize it as a
hookswitch flash signal.
Default
904 ms
Value Range
8 × n (n=3–191) ms
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Card Property
Programming Manual References
None
Feature Manual References
None
DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognize it as a DTMF tone.
Default
30 ms
Value Range
2 × n (n=1–31) ms
Maintenance Console Location
2.7.4 [1-1] Slot—Extension Card Property
2.7 [1] Configuration
PC Programming Manual