Panasonic KX-TDA50 Programming Manual page 76

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

2.6 Help
Q
I cannot set system speed dialing numbers from PC Console.
A
Set the COS of the extension to which PC Console is connected to Manager class, by
setting Manager on the Extension Feature tab of the 2.8.11 [2-7-1] Class of Service—
COS Settings screen to "Enable".
System speed dialing numbers can only be edited by one PC Console at a time.
Q
I have set FWD through system programming, but calls are still not being
forwarded.
A
Perform the following steps:
1.
2.
3.
76
PC Programming Manual
Check that the Call from CO—Present Button Status or Call from Extension—
Present Button Status of the target extension on the 2.10.3 [4-1-2] Wired
Extension—FWD/DND or 2.10.12 [4-2-2] Portable Station—FWD / DND screen is
set to "FWD".
Create a FWD button on the target extension if one does not already exist.
Press the FWD button so that it changes to FWD status.