2.6 Help
A
Perform the following steps:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Q
When modifying the Numbering Plan, I cannot change the Leading Number.
A
It is not possible to use the same Leading Number for 2 extension blocks, or to use a
number that could possibly overlap with another Leading Number.
So, for example, if "2" is already set as a Leading Number it is not possible to set "21" as
another Leading Number because of the possible overlap of extension numbers.
The number you are trying to store cannot be used if it is already being used by:
In any of these cases, choose another number.
Q
When modifying the Numbering Plan, how do I set a 1-digit extension number?
A
Perform the following steps:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Q
How do I change a feature number?
70
PC Programming Manual
Confirm that the Numbering Plan you will change is not currently being used by any
extensions (see 2.4.3 Tool—Extension List View).
If it is being used by extensions, temporarily change the extension numbers of those
extensions to that of another numbering plan, or delete the extension number (see
2.10.1 [4-1-1] Wired Extension—Extension Settings and 2.10.10 [4-2-1]
Portable Station—Extension Settings).
Clear the Leading Number cell.
Click Apply.
Modify the No. of Additional Digits cell as required.
Click Apply.
Enter the desired value in the Leading Number cell.
Click Apply.
Set all extension ports to OUS status.
On the relevant screens, set the extension numbers of extensions to the desired
values.
Set all extension ports back to INS status.
A feature number
Another extension block
A Dial setting (see 2.15.1 [9-1] TIE Table)
Quick Dialing (see 2.8.8 [2-6-1] Numbering Plan—Main—2.8.9 [2-6-2] Numbering
Plan—Quick Dial)
Clear the Leading Number cell.
Click Apply.
Set No. of Additional Digits to "None".
Click Apply.
Enter the desired value in the Leading Number cell.
Click Apply.
Set all extension ports to OUS status.
On the relevant screens, set the extension numbers of extensions to the desired
values.
Set all extension ports back to INS status.