Panasonic KX-TDA50 Installation Manual
Panasonic KX-TDA50 Installation Manual

Panasonic KX-TDA50 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Quick Links

Thank you for purchasing a Panasonic Hybrid IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.
KX-TDA50: PSMPR Software File Version 4.0000 or later
Great user manuals database on
UserManuals.info
Hybrid IP-PBX
Installation Manual
KX-TDA50
Model No.
Document Version: 2007-04
SD Logo is
a trademark.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic KX-TDA50

  • Page 1 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using this product and save this manual for future use. SD Logo is KX-TDA50: PSMPR Software File Version 4.0000 or later a trademark. Document Version: 2007-04 Great user manuals database on UserManuals.info...
  • Page 2 2-Channel Cell Station Unit for 2.4 GHz Portable Station Proprietary Equipment KX-A236 Additional AC Adaptor KX-T30865 Doorphone Compatible Panasonic Proprietary Telephones The Hybrid IP-PBX supports the following telephones: • Digital proprietary telephones (e.g., KX-T7600 series) • Analog proprietary telephones (e.g., KX-T7700 series) •...
  • Page 3 Incompatible Panasonic Proprietary Telephones The Hybrid IP-PBX does not support the following telephones: • KX-T30800 series proprietary telephones and DSS consoles • KX-T61600 series proprietary telephones and DSS consoles • KX-T123200 series proprietary telephones and DSS consoles Notes • For the equipment (e.g., Add-on Key Module, USB Module, Headset ) that can be connected to a particular telephone, refer to the telephone's manual.
  • Page 4 Important Safety Instructions SAFETY REQUIREMENTS When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: Read and understand all instructions. Follow all warnings and instructions marked on the product. Unplug this product from the wall outlet before cleaning.
  • Page 5 SAVE THESE INSTRUCTIONS Installation Manual Great user manuals database on UserManuals.info...
  • Page 6 Precaution WARNING REMOVE MEMORY CARD WHILE POWER SUPPLIED H Y B R I D I P - P B X Doing so may cause the Hybrid IP-PBX to fail to start when you restart the system. Installation Manual Great user manuals database on UserManuals.info...
  • Page 7 Contact your telephone company. If all SLTs operate properly, there may be a problem with your Hybrid IP-PBX. Do not reconnect the Hybrid IP-PBX to the CO lines until it has been serviced by an authorized Panasonic Factory Service Center.
  • Page 8 If a system password is forgotten, it can be found by loading a backup of the system data into a PC, and checking the password using the KX-TDA50 Maintenance Console software. If you do not have a backup of the system data, you must reset the Hybrid IP-PBX to its factory defaults and reprogram it.
  • Page 9 DO NOT send the product to the Executive or Regional Sales offices. They are NOT equipped to make repairs. Product Service Panasonic Factory Service Centers for this product are listed in the service center directory. Consult your certified Panasonic dealer for detailed instructions. For Future Reference Please print, record, and retain the following information for future reference.
  • Page 10 Introduction This Installation Manual is designed to serve as an overall technical reference for the Panasonic Hybrid IP- PBX, KX-TDA50. It provides instructions for installing the hardware, and programming the Hybrid IP-PBX using the KX-TDA50 Maintenance Console. The Structure of this Manual...
  • Page 11 • Telephone numbers to which the system will be connected • Make: Panasonic • Model: KX-TDA50 • Certification No.: found on the side of the unit • Ringer Equivalence No.: 0.3A • Facility Interface Code: 02LS2 •...
  • Page 12 Combined Use with Alarm Equipment If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this equipment does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 13 For Cell Station CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void user's authority to operate this device. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 14: Table Of Contents

    Frame Ground Connection....................40 2.2.6 Installing/Removing the Optional Service Cards...............41 2.2.7 Types of Connectors ......................51 2.2.8 Wall Mounting (KX-TDA50) ....................52 2.2.9 Attaching a Ferrite Core ....................55 2.2.10 Wall Mounting (AC Adaptor)....................56 2.2.11 Surge Protector Installation....................59 Information about the CO Line Cards ................62 2.3.1...
  • Page 15 Overview ......................... 130 Connection ........................131 3.2.1 Connection........................131 Installation of the Hybrid IP-PBX PC Programming Software ........133 3.3.1 Installing and Starting the KX-TDA50 Maintenance Console ......... 133 Troubleshooting.................. 137 Troubleshooting ......................138 4.1.1 Installation........................138 4.1.2 Connection........................140 4.1.3...
  • Page 16 Installation Manual Great user manuals database on UserManuals.info...
  • Page 17: System Outline

    Section 1 System Outline This section provides general information on the Hybrid IP- PBX, including the system capacity and specifications. Installation Manual Great user manuals database on UserManuals.info...
  • Page 18: System Highlights

    PC Phone/PC Console These Panasonic CTI applications can be used on computers connected to each extension, providing their respective extension users with powerful and flexible call handling and display features.
  • Page 19 Portable Station (PS) Features A Panasonic PS can be used in place of a PT to provide wireless access to PBX features and call handling. When in Wireless XDP Parallel Mode, a PS can share an extension number with a wired telephone, allowing extension users to use their PSs when they are away from their desks to answer or make calls as if they were using their wired telephones.
  • Page 20: Basic System Construction

    1.2 Basic System Construction Basic System Construction 1.2.1 Main Unit The main unit is equipped with 4 analog CO line ports (one LCOT4 card) and 4 extension ports (Super Hybrid Ports). For system expansion, optional service cards can be installed, and an additional AC adaptor can also be connected.
  • Page 21: System Connection Diagram

    1.2 Basic System Construction 1.2.2 System Connection Diagram Private CO (Telephone Company) Lines IP Network Analog Remote PC Hybrid IP-PBX Router IP-PT IP Softphone Printer Fax Machine CTI Server External Sensor/ Wireless Phone External Relay Device DSS Console Doorphone & Door Opener DSS Console BGM/Music On Hold (MOH) KX-T7636/...
  • Page 22 1.2 Basic System Construction Hybrid IP-PBX KX-T7636/KX-T7633 LCOT4 DLC8 Telephone Console Analog (KX-TDA5180) (KX-TDA5172) Company CO Line CID4 Voice DLC4 (KX-TDA5193) Processing (KX-TDA5171) System PT-interface CS PS KX-T7600 DPT KX-T7600 DPT IP-GW4 (KX-TDA5480) Private Router IP Network CTI Server Voice Processing System DSS Console...
  • Page 23: Optional Equipment

    1.3 Optional Equipment Optional Equipment 1.3.1 Optional Equipment Maximum Model No. Model Name Description Quantity KX-TDA5105 Memory Expansion Card Memory expansion card to increase system (MEC) data storage space, double the number of DPTs (using Digital XDP connection), and display language selection for VM Menu. To be installed in the MEC slot.
  • Page 24 Hybrid IP-PBX. ITU-T V.90 support. KX-TDA5470 4-Channel VoIP Extension 4-channel VoIP extension card. Compliant with Card (IP-EXT4) Panasonic proprietary protocol, and ITU-T G.729a and G.711 CODEC methods. KX-TDA5480 4-Channel VoIP Gateway 4-channel VoIP gateway card. This card also...
  • Page 25: Specifications

    Non-blocking AC Adaptor AC Input • Panasonic PSLP1244: 100 V AC to 240 V AC; 1.5 A; 50 Hz/60 Hz • Panasonic PSLP1434: 110 V AC to 240 V AC; 1.35 A; 50 Hz/60 Hz DC Output 40 V; 1.38 A (55.2 W) DC Input •...
  • Page 26 1.4 Specifications Extension Connection Cable 1-pair wire (T, R) 1-pair wire (D1, D2) or 2-pair wire (T, R, D1, D2) 2-pair wire (T, R, D1, D2) PT-interface CS 1-pair wire (D1, D2) DSS Console and Add-on Key Module 1-pair wire (D1, D2) Dimension 275 mm (W) ×...
  • Page 27: Characteristics

    1.4 Specifications 1.4.2 Characteristics PT: KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40 Ω Terminal Equipment Loop Limit • SLT: 600 Ω including set • Doorphone: 20 Ω • PT-interface CS: 65 Ω • 15 000 Ω minimum Minimum Leakage Resistance Maximum Number of Extension 1 for PT or SLT Instruments per Line...
  • Page 28: System Capacity

    1.4 Specifications 1.4.3 System Capacity Maximum CO Line and VoIP Line The Hybrid IP-PBX supports the following number of CO lines and VoIP lines. Line Type Maximum Number CO Line VoIP Line Maximum Terminal Equipment The following number of items of terminal equipment can be supported by the Hybrid IP-PBX. Depending on the type and total number of items of equipment to be connected, the MEC card may be required.
  • Page 29 1.4 Specifications Note Devices connected to the Hybrid IP-PBX that exceed the system capacity will not function. MEC Card Calculation Calculate the MEC figure from the type and total number of items of equipment to be connected. If the MEC figure exceeds 28, you need to install an MEC card.
  • Page 30 1.4 Specifications AC Adaptor Selection You must connect an additional AC adaptor in any of the following conditions: • A total of more than 4 APTs, DPTs (except KX-T7600 series), and DSS consoles (except KX-T7600 series) are connected. • More than 4 CSs are connected. •...
  • Page 31: Installation

    Section 2 Installation This section describes the procedures to install the Hybrid IP- PBX. Detailed instructions for planning the installation site, installing the optional service cards, and cabling of peripheral equipment are provided. Further information on system expansion and peripheral equipment installation is included. Installation Manual Great user manuals database on UserManuals.info...
  • Page 32: Before Installation

    2.1 Before Installation Before Installation 2.1.1 Before Installation Please read the following notes concerning installation and connection before installing the Hybrid IP-PBX and terminal equipment. Be sure to comply with all applicable laws, regulations, and guidelines. Safety Installation Instructions When installing telephone wiring, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: Never install telephone wiring during a lightning storm.
  • Page 33 2.1 Before Installation Use 2-pair telephone cables when connecting PTs. Use 1-pair telephone cables when connecting SLTs, data terminals, answering machines, computers, Voice Processing Systems, etc. Unplug the system from its power source when wiring, and plug the system back in only after all wiring is completed.
  • Page 34: Installation Of The Hybrid Ip-Pbx

    2.2 Installation of the Hybrid IP-PBX Installation of the Hybrid IP-PBX 2.2.1 Unpacking Unpack the box and check the items below: Main Unit AC Cord AC Adaptor Screws for Wall Mounting Washers for Wall Mounting Mini Plug (for pager and music source) SD Memory Card Main Strap Strap (for the pre-installed LCOT4 card)
  • Page 35: Names And Locations

    2.2 Installation of the Hybrid IP-PBX 2.2.2 Names and Locations Ground Terminal DC IN 2 DC IN 1 Power Switch SD Memory Card Slot Cover Reset Button System Initialize Switch MOH port Pager port Super Hybrid Ports RS-232C port USB port Installation Manual Great user manuals database on UserManuals.info...
  • Page 36: Opening/Closing The Covers

    2.2 Installation of the Hybrid IP-PBX 2.2.3 Opening/Closing the Covers Opening the Covers Pull the slide button to the right and, holding it, slide the cable cover upwards. Then turn the cable cover slightly to remove it. Slide Button Cable Cover Remove the three screws.
  • Page 37 2.2 Installation of the Hybrid IP-PBX Removing/Attaching the Front Cover If you prefer, you can remove the front cover. Removing the Front Cover Holding the front cover open at about a 45° angle, remove the front cover by pushing it in the direction of the arrow as shown below.
  • Page 38 2.2 Installation of the Hybrid IP-PBX Closing the Covers Close the front cover, then tighten the three screws. Screw Attach the rear hooks on the cable cover to the main unit, then swing the cable cover closed so that the front hooks fit in place.
  • Page 39: Installation Of The Sd Memory Card

    Card CAUTION • Use only the SD Memory Card included with the Hybrid IP-PBX, or a Panasonic optional upgrade SD Memory Card. • The SD Memory Card contains software for all the processes of the Hybrid IP-PBX and all the customer data.
  • Page 40: Frame Ground Connection

    2.2 Installation of the Hybrid IP-PBX 2.2.5 Frame Ground Connection IMPORTANT Connect the frame of the Hybrid IP-PBX to ground. Loosen the screw. Screw Insert a grounding wire (user-supplied)*. Tighten the screw. Connect the grounding wire to ground. Grounding wire To ground * For grounding wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor must be more than 0.75 mm...
  • Page 41: Installing/Removing The Optional Service Cards

    2.2 Installation of the Hybrid IP-PBX 2.2.6 Installing/Removing the Optional Service Cards Slot Position 11 * 10 * 02 * 01 * Slots 10 and 11 accept only cards that do not have external ports. Therefore, these slots do not have removable cover plates.
  • Page 42: Card Slot Number

    2.2 Installation of the Hybrid IP-PBX Card Slot Number Type SVM2 Including one LCOT4 card that is installed by default. Only one of the HLC, DLC4, SLC4 or PLC4 card can be installed. A maximum of two DLC8, SLC8 and PLC8 cards can be installed. CAUTION To protect the main board from static electricity, do not touch parts on the main board or on the optional service cards.
  • Page 43 2.2 Installation of the Hybrid IP-PBX Position the card in the open slot, making sure that the tabs on the both sides of the card fit into place. Then, holding the card firmly in place, lower the rear end so that the hole of the card fits over the extension bolt.
  • Page 44 2.2 Installation of the Hybrid IP-PBX Stick an appropriate optional card label (included) to the left side of the corresponding card. Optional Card Label Connect a cable to an appropriate port of the card. For details about pin assignments, refer to the appropriate section in "2.3 Information about the CO Line Cards"...
  • Page 45 2.2 Installation of the Hybrid IP-PBX Repeat the procedure for other cards. When installing a card in Slot 07, make sure to detach the LED holder first. After installing the card, reattach the LED holder. To detach the LED holder LED holder To attach the LED holder Installation Manual...
  • Page 46 2.2 Installation of the Hybrid IP-PBX When installing a card in Slot 11, tighten the card using the screw included with the card, instead of the extension bolt. Screw Installation Manual Great user manuals database on UserManuals.info...
  • Page 47 2.2 Installation of the Hybrid IP-PBX Cable Handling Attach the strap included with the card to one of the connected cables. Strap Bind all the connected cables together using the strap. Repeat the procedure for other cards. Installation Manual Great user manuals database on UserManuals.info...
  • Page 48 2.2 Installation of the Hybrid IP-PBX Attach the main strap (included with the Hybrid IP-PBX) to any of the 5 rails depending on your preference. Main Strap Installation Manual Great user manuals database on UserManuals.info...
  • Page 49 2.2 Installation of the Hybrid IP-PBX Bind all the connected cables together using the main strap, and then close the cable cover. For how to close the cable cover, refer to "2.2.3 Opening/Closing the Covers". Cable Cover Main Strap Notes •...
  • Page 50 2.2 Installation of the Hybrid IP-PBX Removing the Optional Service Cards Loosen the extension bolt. Holding the protrusions of the card, pull the card in the direction of the arrows. CAUTION When removing the optional service cards, do not put pressure on any parts of the main board (e.g., tall capacitors).
  • Page 51: Types Of Connectors

    2.2 Installation of the Hybrid IP-PBX 2.2.7 Types of Connectors Connector Type Pin Number Used for • DPH4 (KX-TDA5161) RJ11 • HLC4 (KX-TDA5170) • DLC4 (KX-TDA5171) • DLC8 (KX-TDA5172) • SLC4 (KX-TDA5173) • SLC8 (KX-TDA5174) (Twisted pair cable) • PLC4 (KX-TDA5175) •...
  • Page 52: Wall Mounting (Kx-Tda50)

    2.2 Installation of the Hybrid IP-PBX 2.2.8 Wall Mounting (KX-TDA50) Mounting on Wooden Wall Place the reference for wall mounting (on the last page of this manual) on the wall to mark the three screw positions. 130 mm (5-1/8 in)
  • Page 53 2.2 Installation of the Hybrid IP-PBX Mounting on Concrete or Mortar Wall CAUTION Drive mounting screws into the wall. Be careful to avoid touching any metal laths, wire laths or metal plates in the wall. Place the reference for wall mounting (on the last page of this manual) on the wall to mark the three screw positions.
  • Page 54 2.2 Installation of the Hybrid IP-PBX Notes • Do not block the openings of the cabinet. Leave at least 20 cm (8 in) of space above and 10 cm (4 in) to the sides of the Hybrid IP-PBX for ventilation. •...
  • Page 55: Attaching A Ferrite Core

    2.2 Installation of the Hybrid IP-PBX 2.2.9 Attaching a Ferrite Core A ferrite core must be attached when an RJ45 connector is connected to the IP-EXT4 card. Attaching to an RJ45 Connector For the IP-EXT4 Card Wrap the cable once around the ferrite core, then close the case of the ferrite core. Attach the ferrite core 5 cm away from the connector.
  • Page 56: Wall Mounting (Ac Adaptor)

    2.2 Installation of the Hybrid IP-PBX 2.2.10 Wall Mounting (AC Adaptor) Mounting on Wooden Wall Place the reference for wall mounting (on the following page) on the wall to mark the two screw positions. 110 mm (4-5/16 in) Install the screws and washers (included) in the wall. Washer Drive the screw to this position.
  • Page 57 2.2 Installation of the Hybrid IP-PBX Mounting on Concrete or Mortar Wall CAUTION Drive mounting screws into the wall. Be careful to avoid touching any metal laths, wire laths or metal plates in the wall. Place the reference for wall mounting (on the following page) on the wall to mark the two screw positions.
  • Page 58 2.2 Installation of the Hybrid IP-PBX Reference for Wall Mounting Please copy this page and use as a reference for wall mounting. Install a screw here. 110 mm (4-5/16 in) Install a screw here. Note Make sure to set the print size to correspond with the size of this page. If the dimension of the paper output still deviates slightly from the measurement indicated here, use the measurement indicated here.
  • Page 59: 2.2.11 Surge Protector Installation

    2.2 Installation of the Hybrid IP-PBX 2.2.11 Surge Protector Installation Overview A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above ground, or if a telephone line comes into contact with a power line. A surge protector is a device that is connected to a CO line to prevent potentially dangerous electrical surges from entering the building via the CO line and damaging the Hybrid IP-PBX and connected equipment.
  • Page 60 2.2 Installation of the Hybrid IP-PBX Outside Installation (Main Building) Surge Protector CO Line (Another Building) CO Line Extn. Hybrid Terminal IP-PBX Board Surge Extn. Protector Extn. Extn. Ground Extn.: Extension Line If you install an extension outside of the building, the following precautions are recommended: Install the extension wire underground.
  • Page 61 2.2 Installation of the Hybrid IP-PBX Connect the ground rod to the surge protector using a grounding wire with a cross-sectional area of at least 1.3 mm Bury the ground rod near the protector. The grounding wire should be as short as possible. The grounding wire should run straight to the ground rod.
  • Page 62: Information About The Co Line Cards

    2.3 Information about the CO Line Cards Information about the CO Line Cards 2.3.1 LCOT4 Card (KX-TDA5180) Function 4-port analog CO line card with 2 power failure transfer (PFT) ports. One CID4 card can be mounted on the LCOT4 card (refer to "2.3.2 CID4 Card (KX-TDA5193)"). PFT Port 2 PFT Port 1 RJ11...
  • Page 63: Cid4 Card (Kx-Tda5193)

    2.3 Information about the CO Line Cards 2.3.2 CID4 Card (KX-TDA5193) Function 4-port Caller ID signal type FSK/FSK (with Call Waiting Caller ID [Visual Caller ID])/DTMF. To be mounted on the LCOT4 card. CID4 Card LCOT4 Card Accessories and User-supplied Items Accessories (included): none User-supplied (not included): none Note...
  • Page 64: Ip-Gw4 Card (Kx-Tda5480)

    2.3 Information about the CO Line Cards 2.3.3 IP-GW4 Card (KX-TDA5480) Function 4-channel VoIP gateway card. This card also enables CTI communication and system programming via a LAN. Compliant with VoIP H.323 V.2 protocol, and ITU-T G.729a, G.723.1, and G.711 CODEC methods. CSTA Phase 3 protocol compatible.
  • Page 65 2.3 Information about the CO Line Cards Pin Assignments RJ45 Connector (10BASE-T/100BASE-TX) Signal Name Input (I)/Output (O) Function TPO+ Transmit data+ TPO+ TPO- TPI+ TPO- Transmit data- TPI- TPI+ Receive data+ TPI- Receive data- – – Reserved LED Indications Indication Color Description ON LINE...
  • Page 66: Information About The Extension Cards

    2.4 Information about the Extension Cards Information about the Extension Cards 2.4.1 HLC4 Card (KX-TDA5170) Function 4-port extension card for SLTs, APTs, DSS consoles, a Voice Processing System (VPS), and PT-interface CSs. RJ11 To extension Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Note For details about connecting the CS, refer to "2.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
  • Page 67: Dlc4 Card (Kx-Tda5171)

    2.4 Information about the Extension Cards 2.4.2 DLC4 Card (KX-TDA5171) Function 4-port digital extension card for DPTs, DSS consoles, a VPS, and PT-interface CSs. RJ11 To extension Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Note For details about connecting the CS, refer to "2.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
  • Page 68: Slc4 Card (Kx-Tda5173)

    2.4 Information about the Extension Cards 2.4.3 SLC4 Card (KX-TDA5173) Function 4-port extension card for SLTs. RJ11 To extension Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Pin Assignments RJ11 Connector Signal Name Function Ring...
  • Page 69: Plc4 Card (Kx-Tda5175)

    2.4 Information about the Extension Cards 2.4.4 PLC4 Card (KX-TDA5175) Function 4-port extension card for APTs, DSS consoles, and a VPS. RJ11 To extension Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Pin Assignments RJ11 Connector Signal Name...
  • Page 70: Dlc8 Card (Kx-Tda5172)

    2.4 Information about the Extension Cards 2.4.5 DLC8 Card (KX-TDA5172) Function 8-port digital extension card for DPTs, DSS consoles, a VPS, and PT-interface CSs. RJ11 To extensions Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Note For details about connecting the CS, refer to "2.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
  • Page 71: Slc8 Card (Kx-Tda5174)

    2.4 Information about the Extension Cards 2.4.6 SLC8 Card (KX-TDA5174) Function 8-port extension card for SLTs. RJ11 To extensions Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Pin Assignments RJ11 Connector Signal Name Function Ring...
  • Page 72: Plc8 Card (Kx-Tda5176)

    2.4 Information about the Extension Cards 2.4.7 PLC8 Card (KX-TDA5176) Function 8-port extension card for APTs, DSS consoles, and a VPS. RJ11 To extensions Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Strap × 1 User-supplied (not included): RJ11 connector Pin Assignments RJ11 Connector Signal Name...
  • Page 73: Ip-Ext4 Card (Kx-Tda5470)

    2.4 Information about the Extension Cards 2.4.8 IP-EXT4 Card (KX-TDA5470) Function 4-channel VoIP extension card. Compliant with Panasonic proprietary protocol, and ITU-T G.729a and G.711 CODEC methods. RJ45 LEDs To LAN Accessories and User-supplied Items Accessories (included): Ferrite core × 1, Extension Bolt × 1, Strap × 1...
  • Page 74 2.4 Information about the Extension Cards LED Indications Indication Color Description ON LINE Green On-line status indication • ON: At least one port is in use (an IP-PT is connected) • OFF: No ports are in use (no IP-PTs are connected) Note If the LINK indicator is OFF, the ON LINE indicator will also be OFF.
  • Page 75: Information About The Other Cards

    2.5 Information about the Other Cards Information about the Other Cards 2.5.1 DPH4 Card (KX-TDA5161) Function 4-port doorphone card for 4 doorphones, 4 door openers or external relays, and 4 external sensors. 10-pin 8-pin RJ11 Telephone Line Cord To external sensors To door openers/ external relays To doorphones...
  • Page 76 2.5 Information about the Other Cards 8-pin Terminal Block Signal Name Function SENS 1a Sensor Input 1 SENS 1a SENS 1b SENS 1b com 1 SENS 2a SENS 2b SENS 3a SENS 2a Sensor Input 2 SENS 3b SENS 4a SENS 2b com 2 SENS 4b...
  • Page 77 2.5 Information about the Other Cards Connection Diagram for External Sensors and External Relays Power to the external sensor is provided from the DPH4 card and must be grounded through the DPH4 card as indicated in the diagram below. A pair of "sensor" and "common" lines must be connected to the DPH4 card for each external sensor.
  • Page 78: Echo8 Card (Kx-Tda5166)

    To establish a conference call involving 6 to 8 parties, install an ECHO8 card and enable echo cancellation for conferences using the KX-TDA50 Maintenance Console. For details, refer to "Echo Cancel—Conference" in "2.8.17 [2-9] System Options" of the PC Programming Manual.
  • Page 79: Msg2 Card (Kx-Tda5191)

    2.5 Information about the Other Cards 2.5.3 MSG2 Card (KX-TDA5191) Function 2-channel message card. Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Screw × 1 User-supplied (not included): none Installation Manual Great user manuals database on UserManuals.info...
  • Page 80: Svm2 Card (Kx-Tda5192)

    2.5 Information about the Other Cards 2.5.4 SVM2 Card (KX-TDA5192) Function 2-channel simplified voice message card for Simplified Voice Message feature. Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Screw × 1 User-supplied (not included): none Installation Manual Great user manuals database on UserManuals.info...
  • Page 81: Ext-Cid Card (Kx-Tda5168)

    2.5 Information about the Other Cards 2.5.5 EXT-CID Card (KX-TDA5168) Function Sends Caller ID signals to extension ports. Accessories and User-supplied Items Accessories (included): Extension Bolt × 1, Screw × 1 User-supplied (not included): none Installation Manual Great user manuals database on UserManuals.info...
  • Page 82: Mec Card (Kx-Tda5105)

    2.5 Information about the Other Cards 2.5.6 MEC Card (KX-TDA5105) Function Memory expansion card to increase system data storage space, double the number of DPTs (using Digital XDP connection), and display language selection for VM Menu. To be installed in the MEC slot. MEC Card MEC Slot Accessories and User-supplied Items...
  • Page 83 2.5 Information about the Other Cards Removing the MEC Card Pull open the guide rails using a flathead screwdriver and, while holding them open, remove the MEC card. Installation Manual Great user manuals database on UserManuals.info...
  • Page 84: Rmt Card (Kx-Tda5196)

    2.5 Information about the Other Cards 2.5.7 RMT Card (KX-TDA5196) Function Analog modem card for remote communication with the Hybrid IP-PBX. ITU-T V.90 support. RMT Card RMT Slot Accessories and User-supplied Items Accessories (included): none User-supplied (not included): none CAUTION Make sure to insert the RMT card between the guide rails until it locks into the RMT slot.
  • Page 85 2.5 Information about the Other Cards Removing the RMT Card Pull open the guide rails using a flathead screwdriver and, while holding them open, remove the RMT card. Installation Manual Great user manuals database on UserManuals.info...
  • Page 86: Connection Of Extensions

    2.6 Connection of Extensions Connection of Extensions 2.6.1 Maximum Cabling Distances of the Extension Wiring (Twisted Cable) Cable Maximum Distance PT-interface CS 26 AWG: 222 m (728 ft) 24 AWG: 347 m (1138 ft) 22 AWG: 500 m (1640 ft) CAT 5: 347 m (1138 ft) KX-T7600 Series DPT...
  • Page 87 2.6 Connection of Extensions DSS Console PT-interface CS KX-T7600 series Other Super Hybrid Ports (Main Board) SLC4, SLC8 Cards DLC4, DLC8 Cards PLC4, PLC8 Cards HLC4 Card " " indicates that the extension card or Super Hybrid Ports support the terminal. Installation Manual Great user manuals database on UserManuals.info...
  • Page 88: Parallel Connection Of The Extensions

    2.6 Connection of Extensions 2.6.2 Parallel Connection of the Extensions Any SLT can be connected in parallel with an APT or a DPT as follows. Note In addition to an SLT, an answering machine, a fax machine or a modem (PC) can be connected in parallel with an APT and a DPT.
  • Page 89 2.6 Connection of Extensions Using a Modular T-Adaptor To a Super Hybrid Port Modular T-Adaptor 2-conductor wiring cord Connect pins "T" and "R". 4-conductor wiring cord Connect pins "D1" and "D2". Using an EXtra Device Port With KX-T7600 Series DPT To a Super Hybrid Port 2-conductor wiring cord 4-conductor wiring cord...
  • Page 90 2.6 Connection of Extensions With Other DPT To a Super Hybrid Port 2-conductor wiring cord 4-conductor wiring cord Connect pins "T" and "R". Connect pins "T", "R", "D1" and "D2". TO TEL TO EMSS or TO MAIN UNIT To SLT To a Super Hybrid Port Installation Manual Great user manuals database on...
  • Page 91: Digital Extra Device Port (Digital Xdp) Connection

    2.6 Connection of Extensions 2.6.3 Digital EXtra Device Port (Digital XDP) Connection A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected to a Super Hybrid Port, it can also have an SLT connected in Parallel mode or XDP mode. Notes •...
  • Page 92 2.6 Connection of Extensions Using an EXtra Device Port To DLC4/DLC8 card 4-conductor wiring cord To a Super Hybrid Port Connect pins "T", "R", 2-conductor wiring cord (for connection of SLT) "D1" and "D2". Connect pins "T" and "R". 4-conductor wiring cord Connect pins "T", "R", "D1"...
  • Page 93: First Party Call Control Cti Connection

    2.6 Connection of Extensions 2.6.4 First Party Call Control CTI Connection CTI connection between a PC and a KX-T7633/T7636 DPT provides first party call control. The CTI connection is made via a USB interface (version 2.0), and uses the TAPI 2.1 protocol. A USB Module (KX-T7601) must be connected to the KX-T7633/T7636 DPT.
  • Page 94: Connection Of 2.4 Ghz Portable Stations

    This unit determines the area covered by the wireless system. Up to 2 calls can be made at the same time through each CS. PS: 2.4 GHz Portable Station (KX-TD7680/KX-TD7690) The KX-TDA50 can support up to 28 PSs. For more details about the PS, refer to the PS Operating Instructions. CAUTION •...
  • Page 95: Procedure Overview

    2.7 Connection of 2.4 GHz Portable Stations 2.7.2 Procedure Overview When connecting the wireless system, use extreme care in conducting the site survey. An incorrectly performed site survey can result in poor service area, frequent noise, and disconnection of calls. 1.
  • Page 96 2.7 Connection of 2.4 GHz Portable Stations 4. Finish the site survey Refer to "2.7.6 After Site Survey". Return all DIP switches of each CS to the OFF position, and stop supplying power. Turn off the PS. 5. Connect the CS and PS to the Hybrid IP-PBX and test the operation Refer to "2.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
  • Page 97: Site Planning

    2.7 Connection of 2.4 GHz Portable Stations 2.7.3 Site Planning Choosing the best site for the CS requires careful planning and testing of essential areas. The best location may not always be convenient for installation. Read the following information before installing the unit. Understanding the Radio Waves Characteristics of Radio Waves The transmission of radio waves and the CS coverage area depend on the structure and materials of the...
  • Page 98 2.7 Connection of 2.4 GHz Portable Stations Object Material Transmission Tendency Wall Concrete The thicker they are, the less radio waves penetrate them. Ferroconcrete Radio waves can penetrate them, but the more iron there is, the more radio waves are reflected. Window Glass Radio waves usually penetrate them.
  • Page 99 2.7 Connection of 2.4 GHz Portable Stations CS Coverage Area The example below shows the size of the coverage area of 1 CS if it is installed in an area with no obstacles. Note Radio signal strength levels are measured during the site survey (refer to "2.7.5 Site Survey"). Coverage Area Radio signal strength level is greater than "3".
  • Page 100 2.7 Connection of 2.4 GHz Portable Stations one CS becomes weak. However, if a PS moves away from a CS and there are no CSs available for handover, the PS may go out of range and the call could be lost. If the signal from the CS fades, due to the structure of the building, there may be some handover delay.
  • Page 101: Before Site Survey

    2.7 Connection of 2.4 GHz Portable Stations 2.7.4 Before Site Survey Setting and Installing the CS Temporarily for Site Survey Switch the Radio Signal Test switch from OFF to ON. Set the CS number switches as desired. DIP Switch CS Number Switch Keep this switch at the default "OFF"...
  • Page 102 2.7 Connection of 2.4 GHz Portable Stations After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power supply adaptor. Note The AC adaptor should be connected to a vertically oriented or floor-mounted AC outlet. Do not connect the AC adaptor to a ceiling-mounted AC outlet, as the weight of the adaptor may cause it to become disconnected.
  • Page 103: Site Survey

    2.7 Connection of 2.4 GHz Portable Stations 2.7.5 Site Survey The PS has a Radio Signal Test mode that monitors the state of the radio link to the CS. After installing the CSs temporarily, set the PS to Radio Signal Test mode and measure each CS coverage area. Then, record the results on the map of the installation site.
  • Page 104 2.7 Connection of 2.4 GHz Portable Stations Measure the radio signal strength by moving towards and away from the CS. Move to the CS until the radio signal strength level becomes "12". Move away from the CS and identify the CS coverage area within which the radio signal strength level is greater than "8".
  • Page 105 2.7 Connection of 2.4 GHz Portable Stations Overlap the CS coverage areas of at least 2 CSs at any location in the installation site. CS no. 1 CS no. 2 CS no. 3 CS no. 4 Make sure that the radio signal strength level is greater than "3" at any location in the service area required by the user.
  • Page 106 2.7 Connection of 2.4 GHz Portable Stations Deleting the Stored Scan Data Using the KX-TD7680 Scan Data No. Press 1, 9, and POWER 0 to 9, or # for all data for more than 2 seconds. To the Desired Scan Data No. Using the KX-TD7690 Scan Data No.
  • Page 107: After Site Survey

    2.7 Connection of 2.4 GHz Portable Stations 2.7.6 After Site Survey After obtaining the proper measurement results, exit Radio Signal Test mode before connecting the CS to the Hybrid IP-PBX. Keep pressing the POWER button on the PS until the PS is turned OFF. Disconnect the AC adaptor or battery box from the CS and stop supplying electricity.
  • Page 108: Connecting A Cell Station To The Hybrid Ip-Pbx

    2.7 Connection of 2.4 GHz Portable Stations 2.7.7 Connecting a Cell Station to the Hybrid IP-PBX Refer to the following example to connect a CS to the Hybrid IP-PBX. Super Hybrid Port Cable Maximum Distance 26 AWG: 222 m (728 ft) 24 AWG: 347 m (1138 ft) 22 AWG:...
  • Page 109 2.7 Connection of 2.4 GHz Portable Stations Connecting the CS Connect the cable from a Super Hybrid Port or the HLC4/DLC4/DLC8 card to the CS. Modular To a Super Hybrid Port, or HLC4/DLC4/DLC8 card Pass the cable through the groove of the CS (in any direction depending on your preference). TO MAIN UNIT / PABX To a Super Hybrid Port,...
  • Page 110 2.7 Connection of 2.4 GHz Portable Stations Registering the PS The PS must be registered to the Hybrid IP-PBX before it can be used. Programming of both the PS and Hybrid IP-PBX is required. A PT with multiline display (e.g., KX-T7636 6-line display) is required to perform the Hybrid IP-PBX system programming.
  • Page 111 2.7 Connection of 2.4 GHz Portable Stations PS Registration [690] PS No. Extn. No. To the PS operation 001 to 028 1 to 4 digits below ENTER ENTER When the PS has not been registered yet When registering the PS for the first time, it is possible to select the desired language for the display. (You do not need to enter the PS system programming mode when registering for the first time.) Using the KX-TD7680 [ F2 ]...
  • Page 112 2.7 Connection of 2.4 GHz Portable Stations Using the KX-TD7690 CHNG Choose Select "Enable/Disable". "SYSTEM LOCK". ENTR System Lock Password System Lock Password ENABLE 4 digits 4 digits DISABLE ENTR C.Tone Setting the Personal Identification Number (PIN) for PS Registration To prevent registering the PS to a wrong Hybrid IP-PBX, a PIN for PS registration can be set to the Hybrid IP-PBX.
  • Page 113 2.7 Connection of 2.4 GHz Portable Stations PS Termination Confirm the following before canceling the PS registration: • The PS is turned on. • The PS is within range. [691] PS No. 001 to 028 ENTER ENTER If "Rejected" or "Time out" is displayed CLEAR To the PS operation...
  • Page 114: Wall Mounting

    2.7 Connection of 2.4 GHz Portable Stations 2.7.8 Wall Mounting Place the reference for wall mounting (on the following page) on the wall to mark the 2 screw positions. Install the 2 screws and washers (included) into the wall. Notes •...
  • Page 115 2.7 Connection of 2.4 GHz Portable Stations Reference for Wall Mounting Please copy this page and use as a reference for wall mounting. Install a screw here. 71 mm (2-13/16 in) Install a screw here. Note Make sure to set the print size to correspond with the size of this page. If the dimension of the paper output still deviates slightly from the measurement indicated here, use the measurement indicated here.
  • Page 116: Connection Of Doorphones, Door Openers, External Sensors, And External Relays

    2.8 Connection of Doorphones, Door Openers, External Sensors, and External Relays Connection of Doorphones, Door Openers, External Sensors, and External Relays 2.8.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays A maximum of 4 doorphones (KX-T30865), 4 door openers or external relays, and 4 external sensors can be connected to the Hybrid IP-PBX.
  • Page 117 2.8 Connection of Doorphones, Door Openers, External Sensors, and External Relays Pass the wires through the hole in the base cover, and attach the base cover to a wall using 2 screws. Screw To terminal box Note Two kinds of screws are included with KX-T30865. Please choose the appropriate kind for your wall type.
  • Page 118 2.8 Connection of Doorphones, Door Openers, External Sensors, and External Relays Connection of Doorphones Connect DPH4 Card to the terminal boxes using telephone line cords. Refer to "2.5.1 DPH4 Card (KX-TDA5161)" for pin assignments. Connect the wires of doorphones 1 and 3 to the red and green screws on the terminal box. Connect the wires of doorphones 2 and 4 to the yellow and black screws on the terminal box.
  • Page 119 2.8 Connection of Doorphones, Door Openers, External Sensors, and External Relays Connection of Door Openers, External Sensors, and External Relays Use 8-pin and 10-pin terminal blocks (included with the card) for connection. While pressing down on the hole at the top of the terminal block using a screwdriver, insert the wire into the side hole as shown below.
  • Page 120: Connection Of Peripherals

    2.9 Connection of Peripherals Connection of Peripherals 2.9.1 Connection of Peripherals Cable Maximum Distance 26 AWG to 22 AWG: 10 m (32 ft) CAT 5: 10 m (32 ft) BGM/ Cable Maximum Distance Music on Hold 26 AWG to 22 AWG: 10 m (32 ft) CAT 5: 10 m (32 ft) Pager:...
  • Page 121 2.9 Connection of Peripherals Pager Only one paging device (user-supplied) can be connected to the Hybrid IP-PBX. CAUTION An External Paging Jack is a SELV port and should only be connected to an approved SELV device. PC/Printer (via RS-232C) The Hybrid IP-PBX is equipped with an RS-232C interface. This interface provides communication between the Hybrid IP-PBX and the user-supplied devices such as PC or line printers.
  • Page 122 2.9 Connection of Peripherals For connecting a printer/PC with a 25-pin RS-232C connector Hybrid IP-PBX (9-pin) Printer/PC (25-pin) Circuit Type Signal Signal Circuit Type Pin No. Pin No. (EIA) Name Name (EIA) RD (RXD) SD (TXD) RD (RXD) ER (DTR) SD (TXD) ER (DTR) DR (DSR)
  • Page 123 2.9 Connection of Peripherals PC/CTI Server (via USB version 2.0) The Hybrid IP-PBX is equipped with a USB interface. This interface provides communication between the Hybrid IP-PBX and a PC or a CTI server. The PC is used for system programming, diagnostics and external system database storage (save/load) functions.
  • Page 124: 2.10 Power Failure Connections

    2.10 Power Failure Connections 2.10 Power Failure Connections 2.10.1 Power Failure Connections When the power supply to the Hybrid IP-PBX fails, power failure transfer (PFT) will switch from the current connection to the Power Failure Connection. Refer to "1.13.9 Power Failure Transfer" in the Feature Manual for further information.
  • Page 125: 2.11 Starting The Hybrid Ip-Pbx

    2.11 Starting the Hybrid IP-PBX 2.11 Starting the Hybrid IP-PBX 2.11.1 Starting the Hybrid IP-PBX CAUTION • The SD Memory Card must be inserted in the SD Memory Card slot of the main board before startup. • Before touching the System Initialize Switch, discharge static electricity by touching ground or wearing a grounding strap.
  • Page 126 2.11 Starting the Hybrid IP-PBX Plug the DC connector of the AC adaptor into DC IN 1. DC IN 1 DC Connector AC Adaptor Notes • The AC adaptor supplied with the Hybrid IP-PBX must be connected to DC IN 1. If an AC adaptor is connected only to DC IN 2, the Hybrid IP-PBX will not start.
  • Page 127 The DPTs should show the time as 01:00. The data of the IP-GW4 card will not be initialized. IMPORTANT Use only the AC adaptor (Panasonic PSLP1244/Panasonic PSLP1434) and AC cord supplied with the Hybrid IP-PBX, or the Additional AC Adaptor (KX-A236). Installation Manual Great user manuals database on UserManuals.info...
  • Page 128 2.11 Starting the Hybrid IP-PBX LED Indications Indication Color Description Green PBX status indication • OFF: Power off (includes normal reset) • ON: Power on and running (on-line) • Flashing (60 times per minute): Starting up • Flashing (120 times per minute): Starting up or resetting with: •...
  • Page 129: Guide For The Hybrid Ip-Pbx Pc Programming Software

    Section 3 Guide for the Hybrid IP-PBX PC Programming Software This section explains the installation and structure of the Hybrid IP-PBX PC Programming Software. Installation Manual Great user manuals database on UserManuals.info...
  • Page 130: Overview

    Overview KX-TDA50 Maintenance Console is designed to serve as an overall system programming reference for the Hybrid IP-PBX. To program and administer the Hybrid IP-PBX by PC, you need to install the KX-TDA50 Maintenance Console onto the PC. This manual describes overview and installation of the KX-TDA50 Maintenance Console only.
  • Page 131: Connection

    3.2 Connection Connection 3.2.1 Connection Serial Interface Connection RS-232C Port To COM Port To USB Port USB Port Note For pin assignments and maximum cabling distance, refer to "2.9.1 Connection of Peripherals". LAN Connection via IP-GW4 Card RJ45 Switching Hub To network port Note For pin assignments and maximum cabling distance, refer to "2.3.3 IP-GW4 Card (KX-TDA5480)".
  • Page 132 Use an RS-232C straight cable for connection between the Hybrid IP-PBX and external modem. • An AT command (for initialization, enabling automatic answer, etc.) can only be programmed by KX-TDA50 Maintenance Console. "AT&F" is stored as the default value. • For more information about the AT command, refer to the external modem's instructions.
  • Page 133: Installation Of The Hybrid Ip-Pbx Pc Programming Software

    Installing the KX-TDA50 Maintenance Console Notes • Make sure to install and use the latest version of the KX-TDA50 Maintenance Console. • To install or uninstall the software on a PC running Windows 2000 Professional or Windows XP Professional, you must be logged in as a user in either the "Administrators" or "Power Users" group.
  • Page 134 Starting the KX-TDA50 Maintenance Console and Assigning the Basic Items (Quick Setup) When you start the KX-TDA50 Maintenance Console with the Installer Level Programmer Code and connect to the Hybrid IP-PBX for the first time after initialization (with the factory default setting), Quick Setup will launch automatically.
  • Page 135 To save the system data to the SD Memory Card, (1) click the "SD Memory Backup" icon before resetting the Hybrid IP-PBX or turning off the power, or (2) exit the KX-TDA50 Maintenance Console so that the Hybrid IP-PBX automatically saves the system data.
  • Page 136 3.3 Installation of the Hybrid IP-PBX PC Programming Software CAUTION Do not remove the SD Memory Card while power is supplied to the Hybrid IP-PBX. Doing so may cause the Hybrid IP-PBX to fail to start when you try to restart the system. Installation Manual Great user manuals database on UserManuals.info...
  • Page 137: Troubleshooting

    Section 4 Troubleshooting This section provides information on the Hybrid IP-PBX and telephone troubleshooting. Installation Manual Great user manuals database on UserManuals.info...
  • Page 138: Troubleshooting

    4.1 Troubleshooting Troubleshooting 4.1.1 Installation PROBLEM PROBABLE CAUSE SOLUTION Extension does not operate. Bad extension card. • Exchange the card for a known working one. Bad connection between the • Take the telephone and plug it into the Hybrid IP-PBX and telephone. same extension port using a short telephone cord.
  • Page 139 PROBABLE CAUSE SOLUTION The ALARM indicator on the A major system error occurs in • See the error log using the KX-TDA50 front of the cabinet turns on red. the Hybrid IP-PBX. Maintenance Console (refer to "4.1.5 Troubleshooting by Error Log").
  • Page 140: Connection

    4.1 Troubleshooting 4.1.2 Connection Connection between the Hybrid IP-PBX and a PT: CAUSE SOLUTION Can you dial The T/R is connected to the D1/D2. Use the correct cord (the an extension? inner 2 wires are for T/R and the outer 2 wires are for D1/D2).
  • Page 141 4.1 Troubleshooting Connection between the central office and the Hybrid IP-PBX: CAUSE SOLUTION (Continued from the CO line is connected to the T2/T1. Reconnect the CO line to previous page.) the T1/R1 or T2/R2 of the telephone jack using 2-conductor wiring. Can you dial out on a CO line...
  • Page 142: Operation

    4.1 Troubleshooting 4.1.3 Operation PROBLEM PROBABLE CAUSE SOLUTION • When using the • The HANDSET/HEADSET • When the headset is not used, set the speakerphone on an APT, selector is set to the HANDSET/HEADSET selector to the nothing is audible. "HEADSET"...
  • Page 143 4.1 Troubleshooting PROBLEM PROBABLE CAUSE SOLUTION • Noise is frequent while using • Call handover is not • Locate the CS properly (refer to "2.7.5 the PS. working while using the PS. Site Survey" ). • Conversations disconnect • PS is out of CS coverage while using the PS.
  • Page 144: Using The Reset Button

    4.1 Troubleshooting 4.1.4 Using the Reset Button If the Hybrid IP-PBX does not operate properly, use the Reset Button. Before using the Reset Button, try the system feature again to confirm whether there definitely is a problem or not. CAUTION In order to avoid possible corruption of data on the SD Memory Card, please ensure that the "SD ACCESS"...
  • Page 145: Troubleshooting By Error Log

    Below is the display format of the error log. For information about how to view the error log using the KX- TDA50 Maintenance Console, refer to "2.5.8 Utility—Error Log" in the PC Programming Manual. Example: KX-TDA50 Maintenance Console Example: Station Message Detail Recording (SMDR)
  • Page 146 4.1 Troubleshooting Item Description Sub Code The 5-digit sub code of the relevant hardware (1XXYY). • 1: Cabinet number • XX: Slot number 00 to 11 (00: MPR card slot; 01: Super hybrid ports; 02 to 11: Slots for optional service cards) •...
  • Page 147: Appendix

    Section 5 Appendix Installation Manual Great user manuals database on UserManuals.info...
  • Page 148: Revision History

    5.1 Revision History Revision History 5.1.1 PSMPR Software File Version 1.1xxx New Options • System Components Table – KX-TDA5105 Memory Expansion Card (MEC) Changed Contents • 1.4.3 System Capacity Installation Manual Great user manuals database on UserManuals.info...
  • Page 149: Psmpr Software File Version 2.0Xxx

    5.1 Revision History 5.1.2 PSMPR Software File Version 2.0xxx New Options • System Components Table – KX-TDA5920 SD Memory Card for Software Upgrade to Enhanced Version Changed Contents • 1.4.3 System Capacity • 2.8.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays Installation Manual Great user manuals database on UserManuals.info...
  • Page 150: Psmpr Software File Version 3.0Xxx

    5.1 Revision History 5.1.3 PSMPR Software File Version 3.0xxx New Options • System Components Table – KX-TDA5192 2-Channel Simplified Voice Message Card (SVM2) Installation Manual Great user manuals database on UserManuals.info...
  • Page 151: Psmpr Software File Version 4.0Xxx

    5.1 Revision History 5.1.4 PSMPR Software File Version 4.0xxx New Options • System Components Table – KX-TDA5470 4-Channel VoIP Extension Card (IP-EXT4) Changed Contents • 1.4.3 System Capacity • 2.3.3 IP-GW4 Card (KX-TDA5480) • 3.2.1 Connection Installation Manual Great user manuals database on UserManuals.info...
  • Page 152 5.1 Revision History Installation Manual Great user manuals database on UserManuals.info...
  • Page 153: Index

    Index Installation Manual Great user manuals database on UserManuals.info...
  • Page 154 KX-A236 (Additional AC Adaptor) KX-TDA50 Maintenance Console, Connection KX-TDA50 Maintenance Console, Installation Cable Distance KX-TDA50 Maintenance Console, Overview Cable Handling KX-TDA50 Maintenance Console, Password Security Calculation Example KX-TDA50 Maintenance Console, Quick Setup Changed Contents 148, 149, 151 KX-TDA50 Maintenance Console, System Requirements...
  • Page 155 PSMPR Software File Version 2.0xxx Wall Mounting (KX-TDA50) PSMPR Software File Version 3.0xxx Wall Mounting Reference (AC Adaptor) PSMPR Software File Version 4.0xxx Wall Mounting Reference (CS) Wall Mounting Reference (KX-TDA50) Wiring Precautions Quick Setup Remote Card (KX-TDA5196) 24, 84 Reset Button...
  • Page 156 Index Installation Manual Great user manuals database on UserManuals.info...
  • Page 157 Install a Install a screw here. screw here. 130 mm (5-1/8 in) Reference for Wall Mounting Note Make sure to set the print size to correspond with the size of this page. If the dimensions of the paper output still deviate slightly from the measurements indicated here, use the measurements indicated here.
  • Page 158 Copyright: This material is copyrighted by Panasonic Communications Co., Ltd., and may be reproduced for internal use only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic Communications Co., Ltd. © 2004 Panasonic Communications Co., Ltd. All Rights Reserved.

Table of Contents