Panasonic KX-TDA50 Programming Manual page 205

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

For Output (EIO)—Device Type
Selects the type of connected output device (for output ports only).
Default
Door Opener
Value Range
Relay, Ringer, Door Opener
Maintenance Console Location
2.7.28 [1-1] Slot—DPH Card Property (KX-TDA50 only)
Programming Manual References
2.11.6 [5-4] External Relay
Feature Manual References
1.4.10 Door Open
1.5.8 External Relay
For Sensor (EIO)—Input Signal Decision Time
Specifies the minimum duration of continuous input from the triggered sensor before the PBX
recognizes the input and makes a sensor call.
Default
1088 ms
Value Range
32 × n (n=2–255) ms
Maintenance Console Location
2.7.28 [1-1] Slot—DPH Card Property (KX-TDA50 only)
Programming Manual References
None
Feature Manual References
1.5.9 External Sensor
For Sensor (EIO)—Input Signal Detection Reopening Time
Specifies the length of time after the sensor has been triggered during which any further input from
the sensor will be ignored.
Default
20 s
2.7 [1] Configuration
PC Programming Manual
205