Panasonic KX-TDA50 Programming Manual page 124

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

2.7 [1] Configuration
Value Range
0–3000 × 100 ms
Maintenance Console Location
2.7.13 [1-1] Slot—PRI Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T310
Specifies the maximum time that the PBX waits for a continuance message after receiving the
Incoming Call Proceeding message.
Default
1100 × 100 ms
Value Range
0–3000 × 100 ms
Maintenance Console Location
2.7.13 [1-1] Slot—PRI Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T313
Specifies the maximum time that the PBX waits for a reply after sending the Connect message.
Default
40 × 100 ms
Value Range
0–600 × 100 ms
Maintenance Console Location
2.7.13 [1-1] Slot—PRI Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
124
PC Programming Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda100Kx-tda200Kx-tda600

Table of Contents