Lenovo x3530 M4 Installation And Service Manual page 580

Hide thumbs Also See for x3530 M4:
Table of Contents

Advertisement

No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0225
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
816f011b-0701ffff : The connector [PhysicalConnectorElementName] configuration error has
been repaired. (Front USB)
This message is for the use case when an implementation has detected an Interconnect Configuration
was Repaired.
May also be shown as 816f011b0701ffff or 0x816f011b0701ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0267
User Response
No action; information only. Front Video :
• 816f0125-0b01ffff : [ManagedElementName] detected as present. (PCI Riser 1)
This message is for the use case when an implementation has detected a Managed Element is now
Present.
566
Lenovo System x3530 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3530 m47160

Table of Contents