Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
•
800b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
• 800b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted. (Cooling Zone 1)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff
Appendix A. Integrated Management Module II (IMM2) error messages
385