Event Logs - Lenovo x3530 M4 Installation And Service Manual

Hide thumbs Also See for x3530 M4:
Table of Contents

Advertisement

Power-supply LEDs
AC
DC
Error
On
On
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On

Event logs

Error codes and messages are displayed in POST event log, system-event log, integrated management
module (IMM2) event log, and DSA event log.
• POST event log: This log contains the three most recent error codes and messages that were generated
during POST. You can view the contents of the POST event log from the Setup utility (see "Starting the
Setup utility" on page 83). For more information about POST error codes, see Appendix B "UEFI (POST)
error codes" on page 639.
• System-event log: This log contains POST and system management interrupt (SMI) events and all
events that are generated by the baseboard management controller that is embedded in the integrated
management module (IMM). You can view the contents of the system-event log through the Setup
utility and through the Dynamic System Analysis (DSA) program (as IPMI event log).The system-event
log is limited in size. When it is full, new entries will not overwrite existing entries; therefore, you must
periodically clear the system-event log through the Setup utility. When you are troubleshooting an error,
you might have to save and then clear the system-event log to make the most recent events available for
analysis. For more information about the system-event log, see Appendix A "Integrated Management
Module II (IMM2) error messages" on page 279.
120
Lenovo System x3530 M4 Installation and Service Guide
Description
Off
Normal operation
Off
No ac power to the
server or a problem
with the ac power
source.
On
No ac power to
the server or a
problem with the ac
power source and
the power-supply
had detected an
internal problem.
Off
Faulty
power-supply
Faulty
On
power-supply
Off
Power-supply
not fully seated,
faulty system
board, or faulty
power-supply
On
Faulty power
-supply
Power-supply is
On
faulty
Action
1. Check the ac power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the
error remains, check the
power-supply LEDs.
4. Replace the power-supply.
• Make sure that the power cord
is connected to a functioning
power source.
• Replace the power supply.
Replace the power supply.
Replace the power supply.
1. Make sure that the top
cover is closed and latched
correctly.
2. Reseat the power supply.
3. Replace the failing power
supply.
Replace the power supply.
Replace the power supply.
Notes
This is a normal
condition when no ac
power is present.
This happens only
when a second power
supply is providing
power to the server.
Typically indicates a
power-supply is not
fully seated.

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3530 m47160

Table of Contents