Table 12. Light path diagnostics panel LEDs (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If a action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
LED
Description
PCI
An error has occurred on a PCI
card, a PCI bus or on the system
board. An additional LED is lit on
one of the riser cards.
FAN
A fan has failed, is operating too
slowly, or has been removed. The
TEMP LED might also be lit.
TEMP
The system temperature has
exceeded a threshold level. A
failing fan can cause the TEMP
LED to be lit.
MEM
An invalid memory configuration
(both the MEM LED and CONFIG
LED might be lit) or a memory
error has occurred .
116
Lenovo System x3530 M4 Installation and Service Guide
Action
1. Check the system-event log for information about the error.
2. Check the LEDs on the PCI riser cards to identify the
component that caused the error.
3. If you cannot isolate the failing adapter by using the LEDs
and the information in the system-event log, remove one
adapter at a time from the failing PCI bus; and restart the
server after each adapter is removed.
4. Replace the following components, in the order shown,
restarting the server each time:
• PCI riser card
• (Trained technician only) Replace the system board.
1. Check the LEDs on the server.
2. Reseat the failing fan, which is indicated by a lit LED on
the fan.
3. Replace the failing fan.
1. Make sure that the air vents are not blocked.
2. Determine whether a fan has failed. If it has, replace it.
3. Make sure that the heat sink is seated correctly.
4. Make sure that the room temperature is not too high.
See "Server features and specifications" on page 5 and
"System reliability guidelines" on page 32 for the server
temperature information.
Note: Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1. If the MEM LED and the CONFIG LED are lit, the system
issues an invalid memory configuration error. Complete
the following steps to correct the problem:
a. Check the system-event log in the Setup utility or IMM
error messages. Follow steps indicated in Appendix B
"UEFI (POST) error codes" on page 639 and Appendix
A "Integrated Management Module II (IMM2) error
messages" on page 279.
2. If the CONFIG LED is not lit, the system has detected a
memory error. Complete the following steps to correct
the problem:
a. Update the firmware to the latest level (see "Updating
the firmware " on page 79).
b. Reseat or swap the DIMMs.
c. Check the system-event log in the Setup utility or IMM
error messages. Follow steps indicated in Appendix B
"UEFI (POST) error codes" on page 639 and Appendix
A "Integrated Management Module II (IMM2) error
messages" on page 279.