Table 1. Server features and specifications (continued)
The following RAID options are
available for the server:
• ServeRAID H1110 SAS/SATA
Controller for System x
• ServeRAID M1115 SAS/SATA
Controller for System x
• ServeRAID M5110 SAS/SATA
Controller for IBM System x
• ServeRAID M5120 SAS/SATA
Controller for IBM System x
• ServeRAID M5100 Series Battery
Kit for IBM System x
• ServeRAID M5100 Series 512MB
Cache/RAID 5 Upgrade for IBM
System x
• ServeRAID M5100 Series 512MB
Flash/RAID 5 Upgrade for IBM
System x
• ServeRAID M5100 Series Zero
Cache/RAID 5 Upgrade for IBM
System x
• ServeRAID M5100 Series 1GB
Flash/RAID Upgrade for IBM
System x
• ServeRAID C105 for IBM System X
Size:
• Height: 43 mm ( 1.7 inches, 1U)
• Depth: 673.1 mm (26.5 inches)
• Width: 447 mm (17.6 inches)
• Maximum weight: 15.8 kg (33.8 lb)
when fully configured
Acoustical noise emissions:
• Sound power, idling: 6.5 bels
• Sound power, operating: 6.5 bels
EU Regulation 617/2013 Technical Documentation:
International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to
http://www.ibm.com/systems/x/hardware/energy-star/index.html
• Air temperature:
– Server on: 5°C to 40°C (41°F
to 104°F); altitude: 0 to 915 m
(3000 ft)
– Server on: 5°C to 32°C (41°F to
89.6°F); altitude: 915 m (3000
ft) to 2134 m (7000 ft)
– Server on: 5°C to 28°C (41°F to
82.4°F); altitude: 2134 m (7000
ft) to 3050 m (10000 ft)
– Server off: 5°C to 45°C (41° to
113°F)
– Shipment: -40°C to +60°C
(-40°F to 140°F)
• Humidity:
– Server on: 8% to 85%;
maximum dew point: 24°C
(75.2°F); maximum rate of
change 5 °C/hr
– Server off: 8% to 80%;
maximum dew point: 27°C
(80°F)
– Shipment: 5% to 100%
• Design to ASHRAE Class A3:
– Ambient of 35°C to 40°C (95°F
to 104°F), with relaxed support
– Support cloud like workload
with no performance
degradation acceptable
(Turbo-Off)
– Under no circumstance, can
any combination of worst case
workload and configuration
result in system shutdown or
design exposure at 40°C (104°F)
• Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone
or in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
"Particulate contamination" on
page 827.
Approximate heat output:
• Minimum configuration: 406 Btu
per hour (119 watts)
• Maximum configuration: 2627.3
Btu per hour (770 watts)
Electrical input:
• Sine-wave input (50 - 60 Hz)
required
• Input voltage automatically
selected
• Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
• Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
• Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.12 kVA
– Maximum: 0.78 kVA
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
2. The noise emission level stated
is the declared (upper limit)
sound power level, in bels, for
a random sample of machines.
All measurements are made in
accordance with ISO 7779 and
reported in conformance with
ISO 9296.
.