Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the system-event log.
2. Check for an error LED on the system board.
3. Replace any failing device.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
• 80070208-0a01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 1 Fan Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a01ffff or 0x800702080a01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator utility to ensure current system power consumption
is under limitation. For more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
3. Replace power supply n. (n = power supply number) PS 1 OP Fault : PS 1 Therm Fault :