Removing A Usb Embedded Hypervisor Flash Device - Lenovo x3530 M4 Installation And Service Manual

Hide thumbs Also See for x3530 M4:
Table of Contents

Advertisement

Figure 135. RAID adapter battery installation
a.
Orient the battery as shown in the following illustration; then, lower the battery into the RAID
battery tray. If the battery comes with a battery carrier, ensure that battery carrier posts align
with the rings on the battery mounting slot so that the battery carrier is secure in the slot.
Note: The positioning of the remote battery depends on the type of remote battery that you
install.
b.
Rotate the retention clip to the close position and press down on the battery tray cover until it
snaps in place to hold the battery in place.
Step 3.
Connect the remote battery cable to the remote battery cable connector to the ServeRAID adapter.
Route the remote battery cable in the server as shown in the following illustration.
Attention: Make sure that the cable is not pinched and does not cover any connectors or obstruct
any components on the system board.
Step 4.
Reinstall the PCI riser-card assembly (see "Replacing a PCI riser-card assembly" on page 74).
Step 5.
Replace the cover (see "Replacing the server top cover" on page 189).
Step 6.
Reconnect the power cord and any cables that you removed.
Step 7.
Turn on the peripheral devices and the server.

Removing a USB embedded hypervisor flash device

Use this information to remove a USB embedded hypervisor flash device.
To remove a hypervisor flash device, complete the following steps:
Step 1.
Read the safety information that begins in "Safety" on page v and "Installation guidelines" on
page 31.
Step 2.
Turn off the server (see "Turning off the server" on page 22) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
Step 3.
Remove the top cover (see "Removing the server top cover" on page 33).
Step 4.
Remove PCI riser-card assembly 1 (see "Removing a PCI riser-card assembly" on page 241).
Step 5.
Locate the USB embedded hypervisor flash device connector on the system board.
.
Chapter 6
Removing and replacing structural parts
221