Lenovo x3530 M4 Installation And Service Manual page 816

Hide thumbs Also See for x3530 M4:
Table of Contents

Advertisement

Latest level of DSA
Latest level of BMC/IMM
166-805-001 : IMM I2C Test Aborted
Invalid Command for given LUN.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
166-806-001 : IMM I2C Test Aborted
Timeout while processing command.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
802