C.3.3 Code 39 - Psion Teklogix Omnii XT10 User Manual

Table of Contents

Advertisement

Add AIM ID Prefix
The AIM ID (Association for Automatic Identification and Mobility) is an international bar
code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of
the decoded bar code.
C.3.3
Code 39
Enable
Setting this parameter to on enables "Code 39".
Full ASCII
If this parameter is enabled, the characters +, %, and / are used as escape characters. The
combination of an escape character and the next character is converted to an equivalent
ASCII character.
Reading Range
Determines the reading distance from which a bar code can be successfully scanned. The
default setting, Extended, allows for increased reading distance.
Start/Stop Transmit
Setting this parameter to on enables the transmission of start and stop characters, which are
usually not transmitted. Code 39 can start and end with either a * or a $ character (see also
the next parameter).
Accepted Start Char
This parameter allows you the option of using one of the two start/stop characters or both ($
char, * char, $ and * char).
Check Digit Verification
Uses the specified algorithm of the option you've chosen to ensure the integrity of the
symbol data before transmitting. If the data does not contain that algorithm, the data is not
transmitted. The available options are: Disabled, MOD 43 Check, French CIP, or
Italian CIP.
Note: French CIP (French pharmaceutical) is only used with bar codes containing
7 characters.
Italian CIP (Italian pharmaceutical) is also known as Code 32. It is transmitted as a
standard Code 39 if checksum is not validated.
Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Appendix C: Bar Code Settings
Decoded (Intermec ISCP)
Code 39
C-27

Hide quick links: