When the battery has finished charging, the LED turns solid green.
The charge stops when the battery is fully charged and the LED remains green.
A full charge will take 3 to 4 hours for a 5000 mAh battery.
6.7.4

Cleaning the Desktop Docking Station

Important: Do not immerse the unit in water. Dampen a soft cloth with mild detergent
Use only mild detergent or soapy water on a slightly damp cloth to clean the desktop
docking station. Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The
plastic case is susceptible to harsh chemicals. The plastic is partially soluble in oils,
mineral spirits and gasoline. The plastic slowly decomposes in strong alkaline solutions.
To clean ink marks from the label, use isopropyl alcohol.
6.7.5

Troubleshooting

The indicators, applications, and drivers required to use and monitor the desktop docking
station as a dock (as opposed to a charger) are installed on Omnii—no applications are
present on the docking station itself.

6.7.5.1 Docking station does not seem to power on.

When first connected to the DC power supply, the charger LED should flash a sequence
of red, yellow, and green.
If not, the charger is defective and requires service.

6.7.5.2 Omnii charge indicator LED stays off.

When Omnii is docked into a powered desktop docking station and its charge indicator LED
stays off, there could be a problem with the hand-held or with the docking station. Use a
hand-held with a properly functioning charge indicator to isolate the problem.

6.7.5.3 Omnii charge indicator LED is red.

If the Omnii charge indicator is red when the hand-held is docked:
Remove Omnii and disconnect the adaptor DC power cable.
Wait at least 20 seconds, and then plug the cable in again.
If the Omnii indicator still shows a fault, the hand-held requires service.