Appendix C: Bar Code Settings
Decoded (Internal) Scanners

Code 39

C.2.5
Code 39
Enabled
Setting this parameter to on enables "Code 39".
Enable Trioptic Code 39
Note: "Trioptic Code 39" and "Full ASCII" should not be enabled simultaneously. The
scanner does not automatically discriminate between these two symbologies.
Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows
this type of symbology to be recognized.
Convert To Code 32
Note: "Code 39" must be enabled in order for this parameter to function.
Setting this parameter to on allows the scanner to convert the bar code from "Code 39" to
"Code 32".
Code 32 Prefix
Note: "Convert to Code 32" must be enabled in order for this parameter to function.
When this parameter is enabled, the prefix character "A" is added to all "Code 32"
bar codes.
Set Length L1 and Set Length L2
Lengths for "Code 39" can be set for Any length, Length within a range, One discrete length
or Two discrete lengths. The length of a code refers to the number of characters (i.e., human
readable characters), including check digit(s).
Double-tapping on these parameters displays dialog boxes labelled Set Code Lengths where
you can define the code length that will be decoded by your scanner.