FIP-1.5 Too quick jam (jam or pick error)

Procedure
- Initial check -
Are there errors such as use of parts in different
specifications, attachment error, damage,
transformation, dirt, or foreign object?
- Major check parts -
1
GEAR ASSY (PL7.1.1), ROLL ASSY FEED REAR
(PL5.1.36), FEED MOTOR ASSY (PL5.1.28), PWBA
SENSOR (PL4.1.17), REGI SENSOR (mounted on the
PWBA SENSOR), ACTUATOR ASSY REGI
(PL4.1.19),Paper Cassette, PWBA MCU XFABK(B)
(PL9.1.25)
- Paper size check -
2
Is the paper size based on the specifications?
Does any paper remain in the ACTUATOR ASSY
REGI?
3
- MOTOR ASSY MAIN check - *
Does the MOTOR ASSY MAIN rotate normally?
4
Select [MOTOR ASSY MAIN TEST] on the
DIAGNOSTIC MODE MENU.
- ROLL ASSY FEED REAR rotation check - *
5
Does the ROLL ASSY FEED REAR rotate normally?
- FEED MOTOR ASSY check - *
Does the FEED MOTOR ASSY rotate normally?
6
- ACTUATOR ASSY REGI check -
Does the ACTUATOR ASSY REGI run smoothly?
7
- REGI. SENSOR check -
Does the REGI. SENSOR function normally?
8
Select [SENSOR/SWITCH CHECK] on the
DIAGNOSTIC MODE MENU.
*: Do not absolutely touch the powered parts, high-voltage output parts, and driving parts for check.
Check
Chapter 2 Troubleshooting
2.3 Level 2 FIP
Action
YES
Replace and
reattach the parts.
Use the paper
To step 3
based on the
specifications.
- There is a too.
Remove the
paper.
- There is no tool.
Go to FIP-2.7,
To step 5
GEAR ASSY
To step 7
Replace the
FEED MOTOR
To step 7
- There is a tool.
To step 8
Replace the
- There is no tool.
ACTUATOR
Go to FIP-2.4,
ASSY REGI
PWBA SENSOR
error
Replace the
Go to FIP-2.4,
PWBA MCU
PWBA SENSOR
XFABK(B)
NO
To step 2
To step 4
To step 5
error
To step 6
ASSY
error
2-15

Hide quick links:

Advertisement

Table of Contents
loading