Chapter 3 Image Quality Troubleshooting
3.5 Image Quality FIP
FIP-P9 "Toner at determined position"
Toner is detected in some non-print parts.
(This error occurs at almost determined positions.)
- Initial check -
P9
Are there errors such as use of parts in different
specifications, attachment error, damage,
transformation, dirt or foreign object?
- Major check parts -
CASSETTE ASSY 250 CL (PL2.1.1), ROLL BTR
(PL8.1.14)
Item
1
Is toner detected in the lower part?
Is the toner detected in the edge at the end of paper?
2
3
Is the specified paper used?
Is paper set correctly?
4
3-22
Phenomenon/Initial check
Check
Print sample
Action
(at occurrence of error)
Clean the inside of the device.
Check whether the ROLL BTR is
attached normally.
Clean the inside of the device.
Use the specified paper.
Clean the inside of the device and
set papers again.