Image Quality Fip; Fip-P1 "All White - Fuji Xerox DocuPrint 2050 Service Manual

Hide thumbs Also See for DocuPrint 2050:
Table of Contents

Advertisement

Chapter 3 Image Quality Troubleshooting

3.5 Image Quality FIP

3.5 Image Quality FIP

FIP-P1 "All white"

All white (white paper)
No data is printed out, and paper is all white.
- Initial check -
P1
Are there errors such as use of parts in different
specifications, attachment error, damage,
transformation, dirt or foreign object?
- Major check parts -
Drum/toner cartridge (PL10.1.2), ROS ASSY
(PL10.1.1), PWBA MCU (PL9.1.25)
Item
- Drum/toner cartridge error 1 -
1
Does toner remain in the Drum/toner cartridge?
- Drum/toner cartridge error 2 -
2
Is the toner seal pulled out from the Drum/toner
cartridge?
- ROS ASSY connection error -
3
Is the connector normally connected to the ROS
ASSY?
- ROS ASSY data transfer error -
4
Is data normally transferred to the ROS ASSY?
3-14
Phenomenon/Initial check
Check
Print sample
Action
(at occurrence of error)
Replace the Drum/toner
cartridge.
Pull out the toner seal of the
Drum/toner cartridge.
Reconnect the connector of the
ROS ASSY.
When it is normal, replace the
ROS ASSY; otherwise, replace
the PWBA MCU.