Chapter 7 Wiring Data
7.3 Wiring Diagram between Parts
§ 1 PWBA MCU <-> LVPS <-> HARNESS ASSY AC IN
PWBA MCU
XFABK(B)
PL9.1.25
Signal line name
RelayControl (H)
HeaterControl (H)
AC N
AC L
7-10
P/J108
RelayControl(H)
1
HeaterControl(H)
2
GND
3
5VDC
4
GND
5
24VDC
6
24VDC
7
The control signal of heater Relay.
The signal opens the cover or when the alarm of Fuser relation occurs,
becomes the low. Because it uses the 24VDC of the interlock.
The control signal of heater TRIAC.
The signal opens the cover or when the alarm of Fuser relation occurs,
becomes the low. Because it uses the 24VDC of the interlock.
Neutral side of AC input near the power (heater TRIAC power voltage)
Line side of AC input near the power (heater TRIAC power voltage)
LVPS 230
PL9.1.5
P/J301
1
2
TR
RL
F
P/J302
AC L
1
AC N
2
Reference
HARNESS ASSY
AC IN
PL5.1.46
AC N
AC L
§2 to FUSER ASSY
KON655CA