Sensor (Decurler Cam Hp) Lag Jam - Lexmark X95 series Service Manual

Hide thumbs Also See for X95 series:
Table of Contents

Advertisement

Step
Action and questions
6
Is the bridge drive motor
properly connected?
Perform a POR.
7
Does the error continue when
the power is turned off/on?

381.27 Sensor (decurler cam HP) lag jam

Step
Action and questions
Check the sensor (decurler cam
1
HP) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (decurler cam
HP).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
2
Is the sensor (decurler cam HP)
properly connected?
Check the bridge decurler cam
3
clutch for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch FINISHER MOTOR
TESTS.
4. Touch Decurler cam clutch.
Does the above component
make an audible clicking
sound?
4
Is the bridge decurler cam
clutch properly connected?
Yes
Replace the bridge drive motor.
Go to
"Bridge drive motor
removal" on page
4-303.
Replace the finisher controller
PCBA. Go to
"Finisher PCBA
removal" on page
4-353.
Yes
Go to step 3.
Replace the sensor (decurler
cam HP). Go to
"Sensor
(decurler cam HP) removal" on
page
4-318.
Go to step 5.
Replace the bridge decurler cam
clutch. Go to
"Decurler clutch
removal" on page
4-310.
7558-xxx
No
Replace the connection.
Problem resolved
No
Go to step 2.
Replace the connection.
Go to step 4.
Replace the connection.
Diagnostic information
Previous
Next
Go Back
2-193

Advertisement

Table of Contents
loading

Table of Contents