3.11 Adjustment of the Developer Unit

3.11.1
Doctor-to-sleeve gap (black developer unit)
Adjustment tool to use: Doctor-sleeve jig
Adjusting procedure:
(1)
Take off the black developer unit from the equipment.
(2)
Remove 2 screws and take off the developer
material cover. Then discharge the devel-
oper material.
(3)
Remove 2 screws, release the hook and take
off the doctor blade cover.
June 2005 © TOSHIBA TEC
Fig.3-28
Screw
Doctor blade
cover
Fig.3-29
e-STUDIO281c/351c/451c ADJUSTMENT
3 - 57
Developer
material cover
3
Screw
Screw