Control Panel (Blower Switch, A/C Switch, Mode Control Dial, Temperature Control Dial And Recirculation/Fresh Air Selection Switch) - wsm M7060 Workshop Manual

Table of Contents

Advertisement

M6060, M7060, WSM
(4) Control Panel (Blower Switch, A/C Switch, Mode Control Dial,
Temperature Control Dial and Recirculation/Fresh Air Selection Switch)
Blower Switch Connector Voltage
1. Disconnect the 6P connector (2) from blower switch.
2. Turn the main switch to "ON" position.
3. Measure the voltage with a voltmeter across the connector
terminal a and terminal b.
4. If the voltage differs from the battery voltage, the wiring harness,
A/C relay, fuse or main switch is faulty.
Terminal a –
Voltage
Terminal b
(1) Control Panel
(2) 6P Connector
Blower Switch Test
1. Check the continuity through the switch with an ohmmeter.
2. If the continuity specified below are not indicated, the switch is
faulty.
(A) 6P Connector
(Blower Switch Side)
9-S25
Approx. battery voltage
(A) 6P Connector
(Wire Harness Side)
9Y1210828CAS0039US0
9Y1210828CAS0040US0
KiSC issued 08, 2013 A