Check the Fuel Leakage of the Overflow Pipe
1. Connect the fuel hose of air pressure adjustment equipment to
the fuel tube (3).
2. Tighten the valve (4).
3. Connect the air hose to the air pressure adjustment equipment.
4. Adjust air pressure of the regulator (1) between 0.03 and
0.05 MPa (0.3 and 0.5 kgf/cm
5. Open the valve (4) gradually, then add 0.03 MPa (0.3 kgf/cm
4 psi) pressure.
6. Tighten the valve (4).
7. Check the decreased pressure after 4 seconds.
NOTE
• If the decreased pressure is higher than 0.001 MPa
2
(0.01 kgf/cm
, 0.1 psi), it means that there is fuel leakage.
Replace the gasket (5), then check the fuel leakage again.
Decreased pressure after 4 seconds is lower than
Leakage Check
0.001 MPa (0.01 kgf/cm
Specification of components
Parts Name
0.030 to 0.86 MPa
Regulator (1)
0.31 to 8.7 kgf/cm
4.4 to 120 psi
0 to 0.06 MPa
Pressure Gauge (6)
0 to 0.6 kgf/cm
0 to 8 psi
(1) Regulator
(2) Overflow Pipe
(3) Fuel Tube
1-S36
ENGINE
2
, 5 and 7 psi).
2
, 0.1 psi)
Specification or Code No.
2
2
(4) Valve
(5) Gasket
(6) Pressure Gauge
9Y1210828ENS0052US0