T-Joint; R134A Refrigerant Recover And Recycling Machine - wsm M7060 Workshop Manual

Table of Contents

Advertisement

M6060, M7060, WSM

(6) T-joint

(7) R134a Refrigerant Recover and Recycling Machine

T-joint (2) is used to increase efficiency of gas charging using
two refrigerant containers (4) at a time.
1. Install two refrigerant container service valves to T-joint (2)
sides and connect the charging hose (1) to it.
(1) Charging Hose (Green)
(2) T-joint
When there is necessity of discharging the refrigerant on
repairing the tractor, it should use recovery and recycling machine.
(Do not release the refrigerant into the atmosphere.)
IMPORTANT
• Use only R134a refrigerant recovery and recycling
machine, eliminate mixing R134a equipment, refrigerant
and refrigerant oils with R12 systems to prevent
compressor damage.
9-S12
(3) Can Tap Valve
(4) Refrigerant Container
9Y1210828CAS0014US0
9Y1210828CAS0015US0
KiSC issued 08, 2013 A
CABIN