Auxiliary Control Valve Linkage - wsm M7060 Workshop Manual

Table of Contents

Advertisement

M6060, M7060, WSM

[4] AUXILIARY CONTROL VALVE LINKAGE

Adjusting Wire of Auxiliary Control Valve
(Lever Side)
1. Screw in the wire (3) to the rod end (4) fully.
2. Shift the control lever (1) forward and fix the wire with lock nuts
(2) to contact the control lever (1) and stopper (5).
3. Fix the wire (3) with retaining nut (6) center of thread.
(Valve Side)
1. Pull the auxiliary valve lever (8) to a full engage position.
2. Pull out the wire (3) fully, and fix the wire with retaining nuts (7)
to be a clearance (L) between edge of wire end (10) and center
of valve lever pin (9) as shown in the photo.
Clearance (L)
Factory specification
(1) Control Lever
(2) Lock Nut
(3) Wire
(4) Rod End
(5) Stopper
(6) Retaining Nut (Lever Side)
(7) Retaining Nut (Valve Side)
7-S16
HYDRAULIC SYSTEM
0 to 3.0 mm
0 to 0.12 in.
(8) Auxiliary Valve Lever
(9) Lever Pin
(10) Wire End
A : Screw in the wire to the rod end
fully.
L : Clearance
9Y1210828HYS0014US0
KiSC issued 08, 2013 A