Mode Switch; Temperature Control Dial - wsm M108S Workshop Manual

Table of Contents

Advertisement

M108S, WSM

(7) Mode Switch

(8) Temperature Control Dial

Mode Switch Check
1. Disconnect the mode switch 4P connector.
2. Check the continuity through the switch with an ohmmeter.
3. If the continuity specified below is not indicated, check the switch.
Terminal
Position
FACE
Mode switch
FACE / DEF
DEF
(1) Mode Switch
Temperature Control Dial
1. Disconnect the temperature control dial 3P connector.
2. Check the continuity through the dial with an ohmmeter.
3. If the continuity specified below is not indicated, check the dial.
Factory
Resistance
spec.
(1) Temperature Control Dial
10-S27
1
2
A : Mode Switch Side
1 terminal – 3 terminal
Approx. 3 kΩ
1 terminal – 2 terminal
Resistance changes by
2 terminal – 3 terminal
the position of the dial
A : Dial Side
KiSC issued 05, 2012 A
CABIN
3
4
W1042432