TM/P Sensor (front): F, TM/P Sensor (center): C, TM/P Sensor (rear): R, be careful.
2.
Turn on the main power switch, and then go into the SP mode.
3.
Input the characteristic values.
Input data for TM/P Sensor: F into SP3-333. Input data for TM/P sensor: C into SP3-334.
Input data for TM/P sensor: R into SP3-335.
SP No.
Classification 1
3-333-001 ID.Sens TestVal:F
3-333-002 ID.Sens TestVal:F
3-333-003 ID.Sens TestVal:F
3-333-004 ID.Sens TestVal:F
3-333-005 ID.Sens TestVal:F
3-333-006 ID.Sens TestVal:F
3-334-001 ID.Sens TestVal:C
3-334-002 ID.Sens TestVal:C
3-334-003 ID.Sens TestVal:C
3-334-004 ID.Sens TestVal:C
3-334-005 ID.Sens TestVal:C
SM
Classification 2
K2: Check
TM/P sensor: F, value of [1]
Diffuse Corr
TM/P sensor: F, value of [2]
Vct_reg
TM/P sensor: F, value of [3]
Check:Slope
Vct_reg
TM/P sensor: F, value of [4]
Check:Xint
Vct_dif
TM/P sensor: F, value of [5]
Check:Slope
Vct_dif
TM/P sensor: F, value of [6]
Check:Xint
K2: Check
TM/P sensor: C, value of [1]
Diffuse Corr
TM/P sensor: C, value of [2]
Vct_reg
TM/P sensor: C, value of [3]
Check:Slope
Vct_reg
TM/P sensor: C, value of [4]
Check:Xint
Vct_dif
TM/P sensor: C, value of [5]
Check:Slope
4-77
Image Transfer Unit
Value
D146/D147/D148/D149/D150