1.2.3 CHECKING THE HORIZONTAL REGISTRATION

SP6-006-010 (ADF Adjustment L-Edge Regist (1-Pass): Front)
SP6-006-011 (ADF Adjustment L-Edge Regist (1-Pass): Rear)
1.
Copy the original and make sure that the position of the line [B] is within 0±2mm.
2.
If not within the standard, adjust with the SP modes.

1.2.4 CHECKING THE SKEW

SP6-006-012 (ADF Adjustment 1st Buckle (1-Pass))
SP6-006-013 (ADF Adjustment 2nd Buckle (1-Pass))
1.
Make sure that the difference between both end positions of the line [A] is within 0±2mm.
2.
If not within the standard, change the position of the fixing screw [A] to the long hole [B] at the
right hinge.

1.2.5 CHECKING THE MAGNIFICATION

SP6-017-001 (DF Magnification Adj.)
1.
Copy the original and make sure that the length of the line [B] is within 100±1mm.
2.
If not within the standard, adjust with the SP mode.
SM
Adjustment after Replacing the ADF