System 5 Digital Audio Mixing System Operation Manual
Analog Controls
If an ML530 Mic/Line Interface or Modular I/O Remote Preamp is patched to the in-
put, the top four knobs show the analog mic/line controls:
NOTE: If an ML530 Mic/Line Interface or Modular I/O Remote Preamp is not patched
to the input, the top four knobs are blank.
The top knob display shows whether the input is high or low impedance
(HiZ = line; LowZ = mic). Press the lower switch to the left of the knob to
toggle between values.
The second knob display shows whether the 48 V phantom power is on/off.
Press the lower switch to the left of the knob to toggle phantom power on/off.
The third knob display shows whether the high-pass filter is on/off. Press the
lower switch to the left of the knob to toggle the HPF on/off.
The fourth knob controls the analog input gain. Spin the knob to adjust the gain
between -12 and +72 dB.
NOTE: There is a +12dB offset between between the gain knob dB reading and the
Modular I/O Remote Preamp's actual gain position. When the gain knob dis-
plays -12dB, the Modular I/O Remote Preamp's setting is 0dB.
Digital Controls
The bottom four knobs control the digital parameters of the A and B inputs:
The Atrm knob adjusts the digital trim ±15 dB.
Aphs controls the phase of the A input. Press the lower switch to the left of the
knob to toggle the phase. The switch lights to indicate phase reversal. Phase re-
versal is indicated on the TFT screen above the Strip.
Dly controls the delay for both inputs. Press the lower switch to the left of the
knob to enable the delay. The switch lights to indicate the delay is active. Ro-
tate the knob to adjust the delay. The default delay time format is samples
(0 to 2160 range). To change the delay adjust mode on the strip, press the
upper switch to the left of the knob and go to page 3 of the Strip Config Panel
(see page 106), and select between Delay Display Display Modes of Samples,
Seconds/Frames, or Seconds/Milliseconds.
The Inpt knob selects between A, B, and A+B. The selection is indicated on
the TFT screen above the Strip.