800 – 899, Monochrome Video Board Test Error Codes
The 800 series of diagnostic error codes identifies failures with monochrome video boards or
system board functions.
Error Code
802-xx
824-xx
1100 – 1199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board
or system board functions.
Error Code
1101-xx
1109-xx
Monochrome Video Board Test Error Codes
Description
Video memory test failed.
Monochrome video text mode test
failed.
Serial Test Error Codes
Description
Serial port test failed.
Clock register test failed.
Table 3-9
Recommended Action
1.
Replace monitor and retest.
2.
Replace the Advanced VGA board and retest.
3.
Replace monochrome board and retest.
4.
Replace the system board and retest.
Table 3-10
Recommended Action
1.
Check the switch settings on the serial/parallel
interface board (if applicable) and retest.
2.
Replace the serial/parallel interface board
(if applicable) and retest.
3.
Replace the system board and retest.