PAPER FEED
2.4
Replacing the double feed
prevention roller
A. Periodically replaced parts/cycle
• Double feed prevention roller: Every 600,000
copies (Every 500,000 copies in actual replace-
ment count)
B. Procedure
Note:
• Be sure to lower the up/down plate to its lower
most position in advance by pressing the tray
down switch (SW100) with electricity sup-
plied.
1. Remove the LCT from the main body.
2. Open the top cover [1].
3. Remove 2 screws [2] and then remove the pro-
tective cover [3].
4. Remove 2 screws [1] and then remove the dou-
ble feed prevention unit [2].
[1]
[3]
[2]
1-142
C-208 Ver.1.0 Sep 2003
[2]
lt2113014
[1]
lt2113015