Konica Minolta CF5001 Service Manual page 75

Konica minolta cf5001 laser mfp service manual
Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

CF5001 Field Service Ver.1.0 Sep 2003
3. Remove the coupling shaft /A [1] and then
remove the coupling /A [2].
4. Remove 2 screws [3].
5. Remove the position adjusting plate /R [8].
6. Remove the stop ring [4] and then remove the
screw idler gear [5].
7. Remove 3 screws [6] (be careful not to remove
black screw.).
8. Remove the position adjusting plate /F [7].
9. Hold both ends of the drum [9] and raise it up for
removal.
Note:
• Be sure to reinstall the drum so that the cou-
pling side of the drum flange comes to the
rear side of the drum cartridge.
10. Reinstall the above parts following the removal
steps in reverse.
[9]
[7] [5]
[3]
[2]
1-45
PROCESS UNIT
[6]
[4]
[1]
[8]
8050ma3060