Konica Minolta CF5001 Service Manual page 70

Konica minolta cf5001 laser mfp service manual
Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

PROCESS UNIT
5. Stand up the transfer belt unit [1] by using the
front side of the transfer belt unit [1] as the bot-
tom.
6. Remove the screw [2] and release the fixing of
the handle [3].
7. Remove 2 screws [4] and then remove the shaft
stopper [5].
8. Remove the screw [6] and then remove the ten-
sion plate /R [7].
Note:
• When reinstalling the tension plate /R, knock
against the projection of the tension plate /R.
9. Remove 2 screws [8] and then remove the high
voltage supply curler /R [9].
10. Remove the stop ring [10] and then remove the
bearing [11].
Note:
• When reinstalling the stop ring, be sure to
raise the shaft so that the stop ring is set in
the groove of the shaft.
11. Pull up the transfer belt [12] for removal.
Note:
• Be sure to reinstall the transfer belt so that
the rear side stamped with "UP SIDE" at the
edge of the belt comes up.
• When holding the transfer belt by hand, hold it
within 10mm from the upper end. Be careful
not touch any part other than this.
12. Reinstall the above parts following the removal
steps in reverse.
Note:
• Be careful not to touch and/or damage the
transfer belt with bare hands.
• Before installing the belt cleaning unit, coat
the entire surface on the side on the transfer
belt, on which the belt cleaning unit is to be
mounted, with the setting powder.
CF5001 Field Service Ver.1.0 Sep 2003
[4]
[11]
[10]
1-40
[2]
[3] [6]
[12]
[1]
[8]
[9]
8050ma3054
8050ma3152
[7]
[5]