SCANNER
B. Procedure for reinstallation
1. Set the exposure unit [1] into the main body.
2. Move the V-mirror unit [2] to the paper exit side,
and pass an optical positioning jig [3] through
each of the exposure unit [1] and the V-mirror
unit [2] from the front side.
Note:
• When reinstalling the exposure unit, be sure
to use the optical positioning jig.
3. Fasten the exposure unit [1] with 2 screws [4].
4. Remove 2 optical positioning jigs [3].
5. For the subsequent steps, reinstall the parts fol-
lowing the removal steps in reverse.
CF5001 Field Service Ver.1.0 Sep 2003
[2]
1-16
[4]
[1]
[4]
[3]
8050ma3020