CF5001 Field Service Ver.1.0 Sep 2003
4.10 Replacing the transfer belt
A. Screw that must not be removed
Note:
• The screws [1] shown in the drawing below
are not allowed to be removed. Be careful not
to remove them.
B. Periodically replaced parts/cycle
• Transfer belt: Every 200,000 copies
C. Procedure
1. Remove the transfer belt unit. (See "4.5 Remov-
ing and reinstalling the transfer belt unit.")
2. Remove the belt cleaning unit. (See "4.6
Replacing the belt cleaning unit.")
3. Remove the separation claw unit. (See "4.9
Replacing the belt separation claw.")
4. Remove 2 tension springs [1].
[1]
1-39
PROCESS UNIT
[1]
8050ma3148
[1]
8050ma3053