CF5001 Field Service Ver.1.0 Sep 2003
9.25 LCT sheet feed pressure
adjustment
Perform the LCT sheet feed pressure adjustment
when a no feed jam or a double feed jam occurs at
the paper feed.
The sheet feed pressure is affected by the paper
type and the operating environment (the no feed
jam is likely in the low temperature environment and
the double feed is likely in the high temperature
environment).
A. Procedure
1. Remove LCT from the main body.
2. Check the adjusting spring mechanism [2] from
the top left side of the LCT (paper exit side) [1].
3. Change the spring hook position [2] depending
on the symptom.
• The load of the spring changes approximately
10% for a change in its position.
Note:
• Excess adjustment may reverse the symptom.
For example, a no feed jam becomes a double
feed jam.
Weak: Double feed jam is corrected.
Strong: No feed jam is corrected.
2-173
OTHER ADJUSTMENTS
[2]
[1]