OTHER

11. OTHER
11.1 Installation
Counter Socket (OPTION)
A. Procedure
1. Remove the Filter Cover.
See 1.1 Replacing the dust filter /2.
2. Remove the Hinge cover and Scanner cover /R.
See 1.5 Removing and reinstalling the main
board unit.
3. Remove the Key Counter Cover from the Scan-
ner cover /R.
.
4. Remove two screws and the Cover.
5. Use two screws, secure the Key Counter
Socket.
4969D512aa
of
the
Key
Scanner cover /R.
Key Counter Cover
4969D510aa
4969D511aa
1-114
CF5001 Field Service Ver.1.0 Sep 2003
6. Remove dummy connector.
Connect the Key Counter Socket connector.
4969D513aa
Note:
• When the Key Counter Socket is mounted, Set
to the Software DIP Switches.
*25mode: DipSW No.4 Bit.4
Key counter removal recovery.
*25mode: DipSW No.9 Bit.3 - 0
Operation at the counter removal.