Field Service Ver. 1.0 Apr. 2007

Maintenance

2.

Periodical check

2.1

Maintenance procedure (Periodical check parts)

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
2.1.1

Replacing the pick-up roller and feed roller

A. Periodically replaced parts/cycle
• Pick-up roller: Every 200,000 prints
• Feed roller: Every 200,000 prints
[1]
[2]
[2]
1. Open the upper door [1].
4344F2C500DA
2. Remove two screws [1], and remove
the cover [2].
[1]
4344F2C501DA
3. Remove two C-clips [1], and remove
the pick-up roller assy [2].
[1]
4344F2C502DA
2. Periodical check