CF5001 Field Service Ver.1.0 Sep 2003
5. "Printer gamma sensor adj. (LS200) screen"
For the printer gamma sensor adjustment, the
following items are provided. Press the [NEXT
ADJUSTMENT] key or [PREVIOUS ADJUST-
MENT] key to select an item you want to
adjust.
• "Printer gamma sensor adjustment (LS200)"
• "Printer gamma sensor adjustment (LS150)"
• "Printer gamma sensor adjustment (DS200)"
• "Printer gamma sensor adjustment (DS150)"
• "Printer gamma sensor adjustment
• "Printer gamma sensor adjustment (ED)"
The following shows the copy mode to which
each adjustment is reflected:
(LS200): Line screen/High resolution
(LS150): Line screen/Smooth tone
(DS200): Dot screen/High resolution
(DS150): Dot screen/Smooth tone
(CONTONE):
Text section to be used together
with the screens above.
(ED): High compression
Note:
• A screen in which the screen selection is
turned off by the key operator mode-memory
switch is not displayed.
6. Press the [COPY SCREEN] key.
7. With the A4 (for metric machine) or 8.5 x 11
(for inch machine) paper set in the by-pass
tray, press the START button to output a test
pattern.
8. "Please load output paper ... screen"
After completion of the test pattern output, the
display returns automatically to the adjustment
scren.
The outputted test pattern [1] pressed securely
against the original positioning plate /L [3] and
the original positioning plate /R [4], set it to the
original glass.
Note:
Put the green triangular mark [2] on the left
(CONTONE)"
side.
[3]
[2]
9. With 10 sheets of copy paper (white) placed on
the test chart, close the RADF or platen cover.
Note:
• Be sure to use white copy paper. Otherwise,
the printer gradation cannot be corrected
properly.
10. Press the [Start] key.
Note:
• Start cannot be made when paper is not set
in the by-pass tray.
11. When the chart is scanned with no problem
found, the gamma sensor is adjusted, the
printer gamma correction is made and a mes-
sage "Complete" is displayed.