Color Registration (Regcon); Measurement Cycle Test - Lexmark X940e Service Manual

Hide thumbs Also See for X940e:
Table of Contents

Advertisement

7510-XXX
Bar code number
(last 2 digits)
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

Color registration (RegCon)

Measurement cycle test

Step
1
Perform the Measurement cycle test.
1. Enter the Diagnostics Menu.
2. Touch ENGINE ADJUST.
3. Touch RegCon adjust
4. Touch Measurement cycle
Does the above test pass?
2
Check the transfer belt unit assembly for damage.
Does above component show signs of damage on the
frame or on the belt?
4-254
MFP Service Manual
ATC VALUE CONVERSION CHART
Sensitivity gradient default value
708
753
799
844
889
934
526
572
617
663
708
753
799
844
889
934
Check
Standard TC output default value
170
166
162
158
154
150
187
184
180
176
172
168
164
160
156
152
Yes
Perform the
Go to step 2.
"Control sensor
check".
See
"Control
sensor check" on
page
4-256.
Replace the
Go to step 3.
transfer belt unit
assembly.
See
"Transfer
belt unit
assembly
removal" on
page
4-16.
No