7510-XXX
Step
8
Check the ADF feed drive motor assembly for proper
connection.
Is the above component properly connected?
9
Check the inverter solenoid assembly for proper operation.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch Scanner Motor Tests.
4. Touch Inverter solenoid.
Does the above component operate properly?
10
Check the inverter solenoid assembly for proper connection.
Is the above component properly connected?
11
Place an undamaged document in the ADF, and perform a
ADF test.
Does the error remain?
12
Place an undamaged document in the ADF, and perform a
ADF test.
Does the error remain?
2-74
MFP Service Manual
Check
Caution: When performing motor tests, ensure
that all cover and door interlock switches are
overridden.
Yes
Replace the
Replace the
ADF feed drive
connection.
motor assembly.
Go to
"ADF
feed drive
motor
assembly
removal" on
page
4-131.
Go to step 11.
Go to step 10.
Replace the
Replace the
inverter solenoid
connection.
assembly.
Go to
"Inverter
solenoid
assembly
removal" on
page
4-136.
Replace the
Problem solved.
ADF controller
card assembly.
Go to
"ADF
controller card
assembly
removal" on
page
4-135.
Go to step 12.
Replace the RIP
Problem solved.
card assembly.
Go to
"RIP card
assembly
removal" on
page
4-71.
No